Grant: Collaborative Research and Development Grants
University of Waterloo
$48,000.00
Investigation of tendon strains and carpal tunnel pressure during hand held power tool operation
EF 2018-19
Résumé
Hand-held DC power tools are used repetitively by workers in many industries to secure threaded fasteners. Tendonitis and carpal tunnel syndrome are common repetitive strain injuries and the users of hand held power tools suffer from such injuries. The Industrial partner, Honda Canada manufacturing has come up with a concept of an ergonomic device called ""Ergo Arm"". The device consists of an inflatable cuff that inflates when the DC tool is on (thus stabilizing the wrist) and deflates when the DC tool is off. Direct evidence of the effect of this device is needed and optimization of its design is required before it is widely used. *The goal of this project is to characterize the wrist tendon strains and carpal tunnel pressure during DC Hand tool operation and to study the effect of the Ergo Arm device in stabilizing the wrist during such operation. The project also intends to optimize the design of the device so that it has maximum effectiveness. *Several cadaver hands will be dissected and instrumented with sensors to measure tendon strain and carpal tunnel pressure. A dynamic hand simulator will be developed which could apply muscular forces into the tendons of the cadaver arms and apply the same external loads seen during DC hand tool operation. Simulations will be run without and with Ergo Arm device mounted on the wrist. Various design parameters of the device will be varied to find the optimal combination of variables that could result in maximum reduction in tendon strain and carpal tunnel pressure. The project will result in better understanding of wrist loads during manufacturing operations and investigates ways to prevent injuries. The Project could reduce health care costs to the industrial partner and improve the productivity. It could help increase the quality of life for Canadians. *
Programme
Collaborative Research and Development Grants
Bénéficiaire
Emplacement
Ontario, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data
Tel que publié
Application id
511838-2017
Name nom
Chandrashekar, Naveen
Department département
Mechanical Engineering and Mechatronics
Organization id
33
Institution établissement
University of Waterloo
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2018
Competition year année de concours
2017
Award amount
48000
Program id
CRDPJ
Program name en
Collaborative Research and Development Grants
Program name fr
Subventions de recherche et développement coopérative
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
96
Committee name en
RPP Internal Decision Cttee
Committee name fr
Cté de décision interne - PPR
Area of application code
500
Area of application group en
Manufacturing processes and products
Area of application group fr
Procédés et produits industriels
Area of application en
Manufacturing processes and products
Area of application fr
Procédés et produits industriels
Research subject code
1903
Research subject group en
Biomedical engineering
Research subject group fr
Génie biomédical
Research subject en
Biomechanics
Research subject fr
Biomécanique
Partie
2
Nb partie
2
Application title
Investigation of tendon strains and carpal tunnel pressure during hand held power tool operation
Keyword
NSERC
Application summary
Hand-held DC power tools are used repetitively by workers in many industries to secure threaded fasteners. Tendonitis and carpal tunnel syndrome are common repetitive strain injuries and the users of hand held power tools suffer from such injuries. The Industrial partner, Honda Canada manufacturing has come up with a concept of an ergonomic device called ""Ergo Arm"". The device consists of an inflatable cuff that inflates when the DC tool is on (thus stabilizing the wrist) and deflates when the DC tool is off. Direct evidence of the effect of this device is needed and optimization of its design is required before it is widely used. *The goal of this project is to characterize the wrist tendon strains and carpal tunnel pressure during DC Hand tool operation and to study the effect of the Ergo Arm device in stabilizing the wrist during such operation. The project also intends to optimize the design of the device so that it has maximum effectiveness. *Several cadaver hands will be dissected and instrumented with sensors to measure tendon strain and carpal tunnel pressure. A dynamic hand simulator will be developed which could apply muscular forces into the tendons of the cadaver arms and apply the same external loads seen during DC hand tool operation. Simulations will be run without and with Ergo Arm device mounted on the wrist. Various design parameters of the device will be varied to find the optimal combination of variables that could result in maximum reduction in tendon strain and carpal tunnel pressure. The project will result in better understanding of wrist loads during manufacturing operations and investigates ways to prevent injuries. The Project could reduce health care costs to the industrial partner and improve the productivity. It could help increase the quality of life for Canadians. *