Grant: Engage Grants Program
Ryerson University
$25,000.00
Response of liquid storage steel tanks under wind load
EF 2013-14
Résumé
Circular steel tanks are used for liquid storage of many types. They are used in the municipal water supply andfirefighting systems, and are used extensively for storage and/or processing of a variety of liquids andliquid-like materials, including oil, liquefied natural gas, chemical fluids, and wastes of different forms. Mostof these tanks are considered as lifeline facilities and their functional performance is of significance. There aresome concerns on the stability of circular above or at grade steel tanks when they are empty. This condition canoccur when the tanks are still under construction in which the roof has not been placed to stabilize the tank.The tank can fail when subjected to high wind loading. This situation has occurred in many occasions in whichthe tank has buckled as a result of inadequate lateral support. A properly designed tank must be able towithstand the applied loads without any damage. As numbers and sizes of the storage tanks have increased overthe years, so have their importance and the need to better understand their behavior. It is important that rationaland efficient methods for their analysis and design are formulated. This need has been particularly pressing fordeveloping systems that can withstand the applied loads including wind, hurricane and other dynamicexcitations. The objective of the proposed R& D project is to study the effect of wind load variation on theresponse of circular steel tanks and to propose a scheme to improve the response. Currently, there is growingrecognition in the civil engineering communities of the importance of lifeline facilities and the need forsubstantial improvements in the design of such facilities. In particular, there is a lack of information concerningthe broad class of liquid tanks. An improved understanding of the behavior of these types of structures isnecessary to ensure safe and cost-effective standards in Canada. In the proposed research program, the majoremphases will be on providing practical results for the design profession
Programme
Engage Grants Program
Bénéficiaire
Emplacement
Ontario, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data
Tel que publié
Application id
451532-2013
Name nom
Kianoush, Reza
Department département
Civil Engineering
Organization id
43
Institution établissement
Ryerson University
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2013
Competition year année de concours
2013
Award amount
25000
Program id
EGP
Program name en
Engage Grants Program
Program name fr
Programme de subventions d'engagement partenariat
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1553
Committee name en
Ontario Internal Decision Committee
Committee name fr
Comité de décision interne pour l'Ontario
Area of application code
601
Area of application group en
Construction, urban and rural planning
Area of application group fr
Construction, urbanisme et aménagement rural
Area of application en
Structural engineering
Area of application fr
Génie des charpentes
Research subject code
1104
Research subject group en
Structural engineering
Research subject group fr
Génie des structures
Research subject en
Structural analysis
Research subject fr
Analyse des structures
Partie
1
Nb partie
1
Application title
Response of liquid storage steel tanks under wind load
Keyword
NSERC
Application summary
Circular steel tanks are used for liquid storage of many types. They are used in the municipal water supply andfirefighting systems, and are used extensively for storage and/or processing of a variety of liquids andliquid-like materials, including oil, liquefied natural gas, chemical fluids, and wastes of different forms. Mostof these tanks are considered as lifeline facilities and their functional performance is of significance. There aresome concerns on the stability of circular above or at grade steel tanks when they are empty. This condition canoccur when the tanks are still under construction in which the roof has not been placed to stabilize the tank.The tank can fail when subjected to high wind loading. This situation has occurred in many occasions in whichthe tank has buckled as a result of inadequate lateral support. A properly designed tank must be able towithstand the applied loads without any damage. As numbers and sizes of the storage tanks have increased overthe years, so have their importance and the need to better understand their behavior. It is important that rationaland efficient methods for their analysis and design are formulated. This need has been particularly pressing fordeveloping systems that can withstand the applied loads including wind, hurricane and other dynamicexcitations. The objective of the proposed R& D project is to study the effect of wind load variation on theresponse of circular steel tanks and to propose a scheme to improve the response. Currently, there is growingrecognition in the civil engineering communities of the importance of lifeline facilities and the need forsubstantial improvements in the design of such facilities. In particular, there is a lack of information concerningthe broad class of liquid tanks. An improved understanding of the behavior of these types of structures isnecessary to ensure safe and cost-effective standards in Canada. In the proposed research program, the majoremphases will be on providing practical results for the design profession