Canada Spends Logo

Explorez notre analyse du budget 2026

Grant: Engage Grants Program

University of Alberta

$25,000.00

A Hot-Cold Sensation Testing Device

EF 2015-16

Résumé
This project is to develop and build a prototype of a portable hot-cold sensor. This diagnostic device will be used to test and record a patient's sensitivity to hot and cold sensation on the patient's limbs. Loss of sensitivity in limbs can be associated with a variety of neurology disorders or impacts from medical conditions such as diabetes, spinal cord injuries, peripheral neuropathy, stroke and trauma. The device will be portable, to be used in multiple settings such as an examination room, care facilities, or therapy clinics. The test is a non-invasive procedure. Currently, no such portable electronic device exists in which the method to examine hot and cold sensation is standardized. Some clinics use test tubes filled with warm water or cracked ice and water for testing. Temperatures less than 5oC and greater than 45oC elicit painful responses so these temperatures should be avoided. Typically clinicians will ask patients to close their eyes and describe the stimulus when they touch their limbs with different test tubes of various temperatures. Sometimes, a tuning fork will be used as a cool object. These techniques are subjective and highly dependent upon the clinician and therefore, the methods tend to differ between clinics. Clinisys, a company incorporated in Alberta which offers medical products, would like to address these issues by designing and manufacturing a hot-cold sensation testing device. The device integrates the key sensory testing tool, and through its electrical components, provides a means to conduct reproducible tests. The device is targeted to be used by occupational therapists, physicians, neurologists and other healthcare professionals. A rechargeable battery will be used to provide energy to the device. The device will digitally display the temperature of the contact probe, record responses of 3-4 levels of sensitivity and allow users to download the recorded results. The proposed device can also streamline and ease the testing process, add safety, accuracy and efficacy to the existing methods used for the testing of sensation in patients; thus revolutionize the clinical industry.
Programme
Engage Grants Program
Bénéficiaire
Emplacement
Alberta, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data

Tel que publié

Application id
490570-2015
Name nom
Lou, Edmond
Department département
Surgery
Organization id
9
Institution établissement
University of Alberta
Province en
Alberta
Province fr
Alberta
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2015
Competition year année de concours
2015
Award amount
25000
Program id
EGP
Program name en
Engage Grants Program
Program name fr
Programme de subventions d'engagement partenariat
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1555
Committee name en
Prairie Internal Decision Committee
Committee name fr
Comité de décision interne pour les Prairies
Area of application code
513
Area of application group en
Manufacturing processes and products
Area of application group fr
Procédés et produits industriels
Area of application en
Electrical and electronic machinery and equipment (including computer hardware)
Area of application fr
Machinerie et équipement électriques et électroniques (y compris matériel informatique)
Research subject code
2506
Research subject group en
Electrical and electronic engineering
Research subject group fr
Génie électrique et électronique
Research subject en
Electron devices
Research subject fr
Dispositifs électroniques
Partie
1
Nb partie
1
Application title
A Hot-Cold Sensation Testing Device
Keyword
NSERC
Application summary
This project is to develop and build a prototype of a portable hot-cold sensor. This diagnostic device will be used to test and record a patient's sensitivity to hot and cold sensation on the patient's limbs. Loss of sensitivity in limbs can be associated with a variety of neurology disorders or impacts from medical conditions such as diabetes, spinal cord injuries, peripheral neuropathy, stroke and trauma. The device will be portable, to be used in multiple settings such as an examination room, care facilities, or therapy clinics. The test is a non-invasive procedure. Currently, no such portable electronic device exists in which the method to examine hot and cold sensation is standardized. Some clinics use test tubes filled with warm water or cracked ice and water for testing. Temperatures less than 5oC and greater than 45oC elicit painful responses so these temperatures should be avoided. Typically clinicians will ask patients to close their eyes and describe the stimulus when they touch their limbs with different test tubes of various temperatures. Sometimes, a tuning fork will be used as a cool object. These techniques are subjective and highly dependent upon the clinician and therefore, the methods tend to differ between clinics. Clinisys, a company incorporated in Alberta which offers medical products, would like to address these issues by designing and manufacturing a hot-cold sensation testing device. The device integrates the key sensory testing tool, and through its electrical components, provides a means to conduct reproducible tests. The device is targeted to be used by occupational therapists, physicians, neurologists and other healthcare professionals. A rechargeable battery will be used to provide energy to the device. The device will digitally display the temperature of the contact probe, record responses of 3-4 levels of sensitivity and allow users to download the recorded results. The proposed device can also streamline and ease the testing process, add safety, accuracy and efficacy to the existing methods used for the testing of sensation in patients; thus revolutionize the clinical industry.