Canada Spends Logo

Explorez notre analyse du budget 2026

Grant: Idea to Innovation

University of Victoria

$124,872.00

A multi-point sensor to measure pressures across vascular stenoses

EF 2009-10

Résumé
The objective of the proposed research is to complete the development and ex vivo testing of a multi-point pressure sensing system integrated into an angiographic guidewire. This system will be used as a diagnostic tool to assist in therapeutic decisions for percutaneous coronary interventions such as balloon angioplasty and stents. The system will consist of multiple pressure sensors deployed along the length of a single angiographic guide wire. Individual sensors will be based on a common fibre-optic device, the in-fibre Bragg grating. In clinical use, patients will be catheterized by percutaneous femoral approach and the guide wire will be positioned such that the sensors span the target stenosis This system will simultaneously measure dynamic pressures at multiple stations along the length of a stenotic region or, in the case of serial lesions, stenotic regions. It will, therefore, provide physicians with much more detailed and accurate information about the severity of stenoses than existing pressure sensing technologies. Upon completion of this work, the system will be suitable for in vivo testing in an animal model.
Programme
Idea to Innovation
Emplacement
British Columbia, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data

Tel que publié

Application id
380667-2009
Name nom
Wild, Peter
Department département
Mechanical Engineering
Organization id
7
Institution établissement
University of Victoria
Province en
British Columbia
Province fr
Colombie-Britannique
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2009
Competition year année de concours
2009
Award amount
124872
Program id
I2IPJ
Program nane en
Idea to Innovation
Program name fr
De l'idée à l'innovation
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
96
Committee name en
RPP Internal Decision Cttee
Committee name fr
Cté de décision interne - PPR
Area of application code
1211
Area of application group en
Advancement of knowledge
Area of application group fr
Avancement des connaissances
Area of application en
Medical and health sciences
Area of application fr
Sciences médicales et de la santé
Research subject code
1901
Research subject group en
Biomedical engineering
Research subject group fr
Génie biomédical
Research subject en
Biomedical technology
Research subject fr
Technologie biomédicale
Partie
1
Nb partie
1
Application title
A multi-point sensor to measure pressures across vascular stenoses
Keyword
NA
Application summary
The objective of the proposed research is to complete the development and ex vivo testing of a multi-point pressure sensing system integrated into an angiographic guidewire. This system will be used as a diagnostic tool to assist in therapeutic decisions for percutaneous coronary interventions such as balloon angioplasty and stents. The system will consist of multiple pressure sensors deployed along the length of a single angiographic guide wire. Individual sensors will be based on a common fibre-optic device, the in-fibre Bragg grating. In clinical use, patients will be catheterized by percutaneous femoral approach and the guide wire will be positioned such that the sensors span the target stenosis This system will simultaneously measure dynamic pressures at multiple stations along the length of a stenotic region or, in the case of serial lesions, stenotic regions. It will, therefore, provide physicians with much more detailed and accurate information about the severity of stenoses than existing pressure sensing technologies. Upon completion of this work, the system will be suitable for in vivo testing in an animal model.