Canada Spends Logo

Explorez notre analyse du budget 2026

Grant: Discovery Grants Program - Individual

University of Toronto

$38,000.00

High Performance MEMS Platforms for Actuation and Sensing

EF 2024-25

Résumé
We have developed in our research group an ultra-thin (0.5 mm) novel 3-degrees-of-freedom micro-electrostatic actuator platform and shown through implementation examples its potential as a platform that can address long standing problems of micro electrostatic actuators. The micro actuator platform was fabricated and tested to demonstrate large force generation and manipulation of up to 80 mg size masses and a stroke of 100 µm at 150 V. Further development of the technology is needed for its implementation for autofocus (AF) in smart phone cameras and new expanded designs will be pursued to add optical image stabilization (OIS) capability. The camera modules to be developed use the novel actuator to achieve AF based on translation of the image sensor along the optical axis. Such a translation needs to reach a stroke of up to 150 um at 50 V and with a settling time of less than 5 msec. Achieving AF using image sensor actuation provides almost instant focus in which the camera switches the focus form one scene to another in a very short time. Another advantage is the high accuracy (±1um) of the actuator as opposed to ±10 um open loop accuracy of the currently widely used electromagnetic Voice Coil Motor (VCM) technology. This high accuracy enables the use of large aperture cameras which allow more light to reach the image sensor even when the actuators are operated in open loop. The higher stroke at lower voltage requires major changes to the design and micro fabrication process to ensure deeper piston and tube walls and much smaller gaps between various electrode walls to enable a higher stroke at a lower voltage. The OIS feature will be pursued by developing a novel micro electrostatic actuator that offers translation of the image sensor along the optical axis for AF and translations along the plane perpendicular to the optical axis for OIS. The development of such a Silicon chip to jointly enable AF and OIS using one actuator would be a tremendous contribution to miniature camera technology. The camera is widely used in mobile phones and a significant battery drain is observed when used. The micro-actuator platform is expected to significantly reduce the power consumption by using electrostatic actuation technology as opposed to electromagnetic VCMs currently in use. The peak power requirement for micro electrostatic actuators is of the order of 1 mWatt as opposed to 200-500 mWatt for typical VCMs. The micro-electrostatic platform will also be implemented to develop multi-axis accelerometers that are characterized by large range, wide bandwidth, ultra low noise floor and very high sensitivity due to the design itself and is uniquely suitable for a number of applications requiring very high sensitivity. Such technology is in high demand for applications including automotive, action and smartphone cameras and such electrostatic technology moving the image sensor would be the world's first technology to offer simple designs and high reliability.
Programme
Discovery Grants Program - Individual
Bénéficiaire
Emplacement
Ontario, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data

Tel que publié

Application id
RGPIN-2023-03341
Name nom
Ben Mrad, Ridha
Department département
Mechanical and Industrial Engineering
Organization id
31
Institution établissement
University of Toronto
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2024
Competition year année de concours
2023
Award amount
38000
Program id
RGPIN
Program name en
Discovery Grants Program - Individual
Program name fr
Programme de subventions à la découverte - individuelles
Group en
DISCOVERY RESEARCH
Group fr
RECHERCHE AXÉE SUR LA DÉCOUVERTE
Committee code
1512
Committee name en
Mechanical Engineering
Committee name fr
Génie mécanique
Area of application code
517
Area of application group en
Manufacturing processes and products
Area of application group fr
Procédés et produits industriels
Area of application en
Consumer goods
Area of application fr
Produits de consommation
Research subject code
2109
Research subject group en
Mechanical engineering
Research subject group fr
Génie mécanique
Research subject en
Mechanical systems and instrumentation
Research subject fr
Instrumentation et systèmes mécaniques
Field of research list names en
Not available
Field of research list names fr
Non disponible
Socioeconomic objective list names en
Not available
Socioeconomic objective list names fr
Non disponible
Application title
High Performance MEMS Platforms for Actuation and Sensing
Keywords
micro electro mechanical systems; micro fabrication; micro electrostatic actuators; micro mechatronics; piezo electric materials; energy harvesting using piezo electric materials; piezo electric sensors and actuators; miniature cameras
Application summary
We have developed in our research group an ultra-thin (0.5 mm) novel 3-degrees-of-freedom micro-electrostatic actuator platform and shown through implementation examples its potential as a platform that can address long standing problems of micro electrostatic actuators. The micro actuator platform was fabricated and tested to demonstrate large force generation and manipulation of up to 80 mg size masses and a stroke of 100 µm at 150 V. Further development of the technology is needed for its implementation for autofocus (AF) in smart phone cameras and new expanded designs will be pursued to add optical image stabilization (OIS) capability. The camera modules to be developed use the novel actuator to achieve AF based on translation of the image sensor along the optical axis. Such a translation needs to reach a stroke of up to 150 um at 50 V and with a settling time of less than 5 msec. Achieving AF using image sensor actuation provides almost instant focus in which the camera switches the focus form one scene to another in a very short time. Another advantage is the high accuracy (±1um) of the actuator as opposed to ±10 um open loop accuracy of the currently widely used electromagnetic Voice Coil Motor (VCM) technology. This high accuracy enables the use of large aperture cameras which allow more light to reach the image sensor even when the actuators are operated in open loop. The higher stroke at lower voltage requires major changes to the design and micro fabrication process to ensure deeper piston and tube walls and much smaller gaps between various electrode walls to enable a higher stroke at a lower voltage. The OIS feature will be pursued by developing a novel micro electrostatic actuator that offers translation of the image sensor along the optical axis for AF and translations along the plane perpendicular to the optical axis for OIS. The development of such a Silicon chip to jointly enable AF and OIS using one actuator would be a tremendous contribution to miniature camera technology. The camera is widely used in mobile phones and a significant battery drain is observed when used. The micro-actuator platform is expected to significantly reduce the power consumption by using electrostatic actuation technology as opposed to electromagnetic VCMs currently in use. The peak power requirement for micro electrostatic actuators is of the order of 1 mWatt as opposed to 200-500 mWatt for typical VCMs. The micro-electrostatic platform will also be implemented to develop multi-axis accelerometers that are characterized by large range, wide bandwidth, ultra low noise floor and very high sensitivity due to the design itself and is uniquely suitable for a number of applications requiring very high sensitivity. Such technology is in high demand for applications including automotive, action and smartphone cameras and such electrostatic technology moving the image sensor would be the world's first technology to offer simple designs and high reliability.