Canada Spends Logo

Explorez notre analyse du budget 2026

Grant: Research Tools and Instruments - Category 1 (<$150,000)

Université de Montréal

$44,910.00

In vivo measures of rotator cuff muscle dynamics

EF 2010-11

Résumé
The equipment requested is to be used in the in-vivo validation of shoulder complex model in determining the sheltered arm position in a shoulder orthosis to speed up rehabilitation after rotator cuff surgery. Three measuring devices are requested. A 16 channel fine wire intra-muscular electromyography (EMG) system will be used to monitored rotator cuff muscle activations during shoulder surgery. The in-vivo muscle stress/strain sensors (Arthroscopically Insertable Force Probes, AIFP and the Differential Variable Reluctance Transducers, DVRT) will be attached to the muscle tendon during tear repair surgery. These equipments will be used by 5 full-time professors who presently supervise 15 students and assistants in the Simulation and Movement Modeling laboratory. Presently only indirect measures are available to validate the shoulder complex muscle activations since none of the rotator cuff muscles forces which are deep muscles and where most of the injuries take place can be estimated. The fine wire EMG and the miniature AIFP-DVRT sensors will enable direct stress/strain measurements. This information will be crucial to validate the shoulder complex model but also provide unique force data on injured muscles. It will also supply in-situ information to the orthopedic surgeons in combination with a real time kinematical analysis. This could lead to better treatment both surgically and post-operatively through shoulder/arm bracing.
Programme
Research Tools and Instruments - Category 1 (<$150,000)
Emplacement
Quebec, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data

Tel que publié

Application id
406090-2011
Name nom
Begon, Mickael
Department département
Kinésiologie
Organization id
63
Institution établissement
Université de Montréal
Province en
Québec
Province fr
Québec
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2010
Competition year année de concours
2011
Award amount
44910
Program id
EQPEQ
Program name en
Research Tools and Instruments - Category 1 (<$150,000)
Program name fr
Outils et instruments de recherche - catégorie 1 (<150 000$)
Group en
Discovery grants programs
Group fr
Programmes de subventions à la découverte
Committee code
1512
Committee name en
Mechanical Engineering
Committee name fr
Génie mécanique
Area of application code
1102
Area of application group en
Health, education and social services
Area of application group fr
Santé publique, éducation et services sociaux
Area of application en
Biomedical engineering
Area of application fr
Génie biomédical
Research subject code
1903
Research subject group en
Biomedical engineering
Research subject group fr
Génie biomédical
Research subject en
Biomechanics
Research subject fr
Biomécanique
Partie
1
Nb partie
1
Application title
In vivo measures of rotator cuff muscle dynamics
Keyword
NSERC
Application summary
The equipment requested is to be used in the in-vivo validation of shoulder complex model in determining the sheltered arm position in a shoulder orthosis to speed up rehabilitation after rotator cuff surgery. Three measuring devices are requested. A 16 channel fine wire intra-muscular electromyography (EMG) system will be used to monitored rotator cuff muscle activations during shoulder surgery. The in-vivo muscle stress/strain sensors (Arthroscopically Insertable Force Probes, AIFP and the Differential Variable Reluctance Transducers, DVRT) will be attached to the muscle tendon during tear repair surgery. These equipments will be used by 5 full-time professors who presently supervise 15 students and assistants in the Simulation and Movement Modeling laboratory. Presently only indirect measures are available to validate the shoulder complex muscle activations since none of the rotator cuff muscles forces which are deep muscles and where most of the injuries take place can be estimated. The fine wire EMG and the miniature AIFP-DVRT sensors will enable direct stress/strain measurements. This information will be crucial to validate the shoulder complex model but also provide unique force data on injured muscles. It will also supply in-situ information to the orthopedic surgeons in combination with a real time kinematical analysis. This could lead to better treatment both surgically and post-operatively through shoulder/arm bracing.