Canada Spends Logo

Explorez notre analyse du budget 2026

Grant: Discovery Grants Program - Individual

Université de Montréal

$50,000.00

Shear wave based quantitative ultrasound imaging methods

EF 2023-24

Résumé
BACKGROUND: Clinical ultrasound (US) scanners typically provide brightness mode (B-mode) images where the acoustic impedance contrast between tissue structures is used to identify boundaries for diagnosis. Modern US systems also include Doppler modes (with or without contrast agents) for flow and tissue motion analysis, and elastography modes (strain and shear wave (SW) based) for assessing mechanical properties of tissues. Quantitative US (QUS) imaging is another field that aims at quantifying acoustic compression wave interactions with biological tissues. QUS techniques extract fundamental physical properties of tissues to provide information on sub-resolution properties that are not visible on B-mode or other imaging modes. STATE-OF-THE-ART POSITIONING: Since biological soft tissues are hydrated, viscoelasticity is suitable to represent their solid-like behavior using elasticity, and fluid-like behavior using viscosity. However, the assessment of elasticity through US imaging has been more often exploited than viscosity. In US elastography, SWs are usually generated through focused push beams followed immediately by the monitoring of the SW motion. Under certain assumptions, elasticity relies on the measurement of the SW speed, and viscosity on its frequency dispersion or SW attenuation. I will pursue the development of robust viscosity methods for SW elastography imaging. Also, based on intriguing preliminary data on changes in QUS backscatter properties during SW propagation, I am also proposing the development of a new field that I label: "Dynamic QUS backscatter imaging". OBJECTIVES: 1) Improve robustness of tissue viscosity assessment using SW propagation properties; 2) develop a new QUS concept based on SW propagation; 3) validate SW-based viscosity and QUS imaging methods using simulations, in vitro phantom data, and available in vivo human scans; and 4) develop an open-access simulation package combining SW tissue excitation and compression wave backscatter analysis for dynamic QUS backscatter imaging. HYPOTHESES: 1) SW attenuation imaging can be improved by allowing the spectral content of SWs to vary spatially, by no longer assuming a linear power law dependency for the attenuation, and by using a randomized sample consensus algorithm to seek attenuation versus distance in the framework of an optimization process. 2) The dynamic QUS backscatter method should reflect the correlation length of scatterers, which determines constructive and destructive compression wave interferences modulated by the SW propagation. The new dynamic QUS backscatter method may image local tissue oscillating scatterer size and position changes, and provide a new image contrast reflecting pathological states (different from standard backscatter QUS, SW speed, or SW attenuation). CONCLUSION: The development of SW-based technologies (viscosity and backscatter) should provide new imaging modalities for better biological tissue characterization.
Programme
Discovery Grants Program - Individual
Emplacement
Quebec, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data

Tel que publié

Application id
RGPIN-2022-03729
Name nom
Cloutier, Guy
Department département
Radiologie, radio-oncologie et médecine nucléaire - Radiologie, radio-oncologie et médecine nucléaire
Organization id
63
Institution établissement
Université de Montréal
Province en
Québec
Province fr
Québec
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2023
Competition year année de concours
2022
Award amount
50000
Program id
RGPIN
Program name en
Discovery Grants Program - Individual
Program name fr
Programme de subventions à la découverte - individuelles
Group en
DISCOVERY RESEARCH
Group fr
RECHERCHE AXÉE SUR LA DÉCOUVERTE
Committee code
1505
Committee name en
Physics
Committee name fr
Physique
Area of application code
1102
Area of application group en
Health, education and social services
Area of application group fr
Santé publique, éducation et services sociaux
Area of application en
Biomedical engineering
Area of application fr
Génie biomédical
Research subject code
1900
Research subject group en
Biomedical engineering
Research subject group fr
Biomedical engineering
Research subject en
Génie biomédical
Research subject fr
Génie biomédical
Application title
Shear wave based quantitative ultrasound imaging methods
Keyword
Dynamic quantitative ultrasound imaging; Homodyned-K distribution imaging; Quantitative ultrasound imaging; Shear wave attenuation; Shear wave induced tissue motion; Shear wave speed; Ultrasound backscatter coefficient; Ultrasound backscatter statistics
Application summary
BACKGROUND: Clinical ultrasound (US) scanners typically provide brightness mode (B-mode) images where the acoustic impedance contrast between tissue structures is used to identify boundaries for diagnosis. Modern US systems also include Doppler modes (with or without contrast agents) for flow and tissue motion analysis, and elastography modes (strain and shear wave (SW) based) for assessing mechanical properties of tissues. Quantitative US (QUS) imaging is another field that aims at quantifying acoustic compression wave interactions with biological tissues. QUS techniques extract fundamental physical properties of tissues to provide information on sub-resolution properties that are not visible on B-mode or other imaging modes. STATE-OF-THE-ART POSITIONING: Since biological soft tissues are hydrated, viscoelasticity is suitable to represent their solid-like behavior using elasticity, and fluid-like behavior using viscosity. However, the assessment of elasticity through US imaging has been more often exploited than viscosity. In US elastography, SWs are usually generated through focused push beams followed immediately by the monitoring of the SW motion. Under certain assumptions, elasticity relies on the measurement of the SW speed, and viscosity on its frequency dispersion or SW attenuation. I will pursue the development of robust viscosity methods for SW elastography imaging. Also, based on intriguing preliminary data on changes in QUS backscatter properties during SW propagation, I am also proposing the development of a new field that I label: "Dynamic QUS backscatter imaging". OBJECTIVES: 1) Improve robustness of tissue viscosity assessment using SW propagation properties; 2) develop a new QUS concept based on SW propagation; 3) validate SW-based viscosity and QUS imaging methods using simulations, in vitro phantom data, and available in vivo human scans; and 4) develop an open-access simulation package combining SW tissue excitation and compression wave backscatter analysis for dynamic QUS backscatter imaging. HYPOTHESES: 1) SW attenuation imaging can be improved by allowing the spectral content of SWs to vary spatially, by no longer assuming a linear power law dependency for the attenuation, and by using a randomized sample consensus algorithm to seek attenuation versus distance in the framework of an optimization process. 2) The dynamic QUS backscatter method should reflect the correlation length of scatterers, which determines constructive and destructive compression wave interferences modulated by the SW propagation. The new dynamic QUS backscatter method may image local tissue oscillating scatterer size and position changes, and provide a new image contrast reflecting pathological states (different from standard backscatter QUS, SW speed, or SW attenuation). CONCLUSION: The development of SW-based technologies (viscosity and backscatter) should provide new imaging modalities for better biological tissue characterization.