Canada Spends Logo

Explorez notre analyse du budget 2026

Grant: Idea to Innovation

University of Toronto

$121,000.00

Rapid Hi-Fi Magnetic Resonance Imaging (NSERC i2i Phase 1)

EF 2023-24

Résumé
Rapid High-Fidelity (Hi-Fi) magnetic resonance imaging (MRI) is the concept of acquiring images very rapidly without sacrificing spatial resolution, or Hi-Fi definition. This is the panacea in medical imaging, where rapid, real-time acquisitions can open the door to probing dynamic events. Unfortunately, because existing solutions always trade off spatial definition for speed, acceleration is ultimately limited to maintain diagnostic quality. SPARS is a solution to rapid Hi-Fi MRI, preserving spatial resolution while requiring one measurement only, equivalent to one line in the acquisition domain, to reconstruct an image in a dynamic scan. Compared to competing state-of-the-art rapid acquisition and reconstruction methods (e.g. GRASP/GRASP-Pro), SPARS is at least 2-4x faster and increases reconstruction accuracy by 100x. This technology, developed at the University of Toronto, is agnostic to the vendor of MR scanner and can be integrated into the acquisition-reconstruction workflow for the following applications: (1) dynamic perfusion MRI for cancer diagnosis and therapy monitoring, (2) vasoreactivity MRI of vessel health in brain injury and disease, (3) real-time MRI for image-guided ablation therapy, and (4) stress MRI testing in the heart. The breadth of applications that can benefit from SPARS has already attracted the interest of United Imaging (leading manufacturer of clinical MR scanners) and Synaptive (Canadian manufacturer of low-field MR scanners for image-guided neurosurgery). The key ideas on which SPARS is based are being patented. In its current version, it learns the anatomical structures contained in a dynamic MRI scan and then reconstructs one image from as few as one measurement. The fewer the measurements required for reconstruction, the faster the temporal resolution. At this acceleration rate, state-of-the-art GRASP and GRASP-Pro completely fail, producing indiscernible images. SPARS has been tested on simulated human brain data and real in-vivo human abdominal MRI. The superb reconstruction quality of SPARS at unprecedented acceleration rates will be expanded to include cardiac and image-guided MRI, strengthening its value across the key diagnostic domains.
Programme
Idea to Innovation
Bénéficiaire
Emplacement
Ontario, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data

Tel que publié

Application id
586098-2023
Name nom
Cheng, Hai-Ling HLM
Department département
Biomedical Engineering, Institute of (BME)
Organization id
31
Institution établissement
University of Toronto
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2023
Competition year année de concours
2023
Award amount
121000
Program id
I2IPJ
Program name en
Idea to Innovation
Program name fr
De l'idée à l'innovation
Group en
RESEARCH PARTNERSHIPS
Group fr
PARTENARIATS DE RECHERCHE
Committee code
96
Committee name en
RPP Internal Decision Cttee
Committee name fr
Cté de décision interne - PPR
Area of application code
1101
Area of application group en
Health, education and social services
Area of application group fr
Santé publique, éducation et services sociaux
Area of application en
Human health (including medically-related psychological research)
Area of application fr
Santé publique (y compris recherche psychologique liée à la médecine)
Research subject code
2514
Research subject group en
Electrical and electronic engineering
Research subject group fr
Digital signal processing
Research subject en
Génie électrique et électronique
Research subject fr
Traitement des signaux numériques
Application title
Rapid Hi-Fi Magnetic Resonance Imaging (NSERC i2i Phase 1)
Keyword
dynamic imaging; image reconstruction; magnetic resonance imaging; perfusion imaging; real-time imaging; sparse data acquisition
Application summary
Rapid High-Fidelity (Hi-Fi) magnetic resonance imaging (MRI) is the concept of acquiring images very rapidly without sacrificing spatial resolution, or Hi-Fi definition. This is the panacea in medical imaging, where rapid, real-time acquisitions can open the door to probing dynamic events. Unfortunately, because existing solutions always trade off spatial definition for speed, acceleration is ultimately limited to maintain diagnostic quality. SPARS is a solution to rapid Hi-Fi MRI, preserving spatial resolution while requiring one measurement only, equivalent to one line in the acquisition domain, to reconstruct an image in a dynamic scan. Compared to competing state-of-the-art rapid acquisition and reconstruction methods (e.g. GRASP/GRASP-Pro), SPARS is at least 2-4x faster and increases reconstruction accuracy by 100x. This technology, developed at the University of Toronto, is agnostic to the vendor of MR scanner and can be integrated into the acquisition-reconstruction workflow for the following applications: (1) dynamic perfusion MRI for cancer diagnosis and therapy monitoring, (2) vasoreactivity MRI of vessel health in brain injury and disease, (3) real-time MRI for image-guided ablation therapy, and (4) stress MRI testing in the heart. The breadth of applications that can benefit from SPARS has already attracted the interest of United Imaging (leading manufacturer of clinical MR scanners) and Synaptive (Canadian manufacturer of low-field MR scanners for image-guided neurosurgery). The key ideas on which SPARS is based are being patented. In its current version, it learns the anatomical structures contained in a dynamic MRI scan and then reconstructs one image from as few as one measurement. The fewer the measurements required for reconstruction, the faster the temporal resolution. At this acceleration rate, state-of-the-art GRASP and GRASP-Pro completely fail, producing indiscernible images. SPARS has been tested on simulated human brain data and real in-vivo human abdominal MRI. The superb reconstruction quality of SPARS at unprecedented acceleration rates will be expanded to include cardiac and image-guided MRI, strengthening its value across the key diagnostic domains.