Grant: Discovery Grants Program - Individual
Ryerson University
$21,000.00
Utilization of high strength concrete for offshore applications
EF 2010-11
Résumé
The current research proposal is focused on the development and optimization of a new crack design criteria and minimum reinforcement suitable for high strength concrete with thick concrete cross sections, thick concrete covers, large diameter reinforcement and relatively high reinforcement ratios. Offshore structures are exposed to harsh environmental conditions, including exposure to seawater and sea spray or the structure's existence in the splash zone. An accurate estimate of the crack width and steel reinforcement can result in saving estimated to be in millions of dollars for a single platform. Most of the available expressions for crack width calculations were developed for building structures using normal strength concrete and normal concrete cover. However, offshore structures are built using high strength concrete with thick concrete sections up to 500 mm with 50 - 60 mm concrete cover. Very little research information is published on the crack analysis of high strength concrete with thick concrete section and large concrete cover used for offshore applications. The proposed numerical phase of the investigation will examine mechanisms associated with tension and flexure cracking. Other factors that affect crack width and spacing of cracks under sustained service loads will be examined. Previous important investigations conducted by the applicant on high strength concrete for offshore applications will be utilized to evaluate accurately the cracking properties of offshore structures.
High strength concrete reinforced with glass fiber reinforcement (GFRP) bars has great potential for offshore applications. The utilization of glass bars in panel-type structures requires better understanding of its cracking and tensile behaviour. The use of a non-corrosive material for concrete reinforcement will improve the structure durability and will provide great economical advantage. The current investigation will examine concrete plates reinforced with GFRP bars under uniaxial, biaxial and flexure loads. A constitutive relationship that can describe the response of the GFRP-reinforced concrete panels is being investigated.
Programme
Discovery Grants Program - Individual
Bénéficiaire
Emplacement
Ontario, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data
Tel que publié
Application id
4400-2007
Name nom
Marzouk, Hesham
Department département
Civil Engineering
Organization id
43
Institution établissement
Ryerson University
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2010
Competition year année de concours
2007
Award amount
21000
Program id
RGPIN
Program name en
Discovery Grants Program - Individual
Program name fr
Programme de subventions à la découverte - individuelles
Group en
Discovery grants programs
Group fr
Programmes de subventions à la découverte
Committee code
6
Committee name en
Civil Engineering
Committee name fr
Génie civil
Area of application code
601
Area of application group en
Construction, urban and rural planning
Area of application group fr
Construction, urbanisme et aménagement rural
Area of application en
Structural engineering
Area of application fr
Génie des charpentes
Research subject code
1103
Research subject group en
Structural engineering
Research subject group fr
Génie des structures
Research subject en
Concrete structures
Research subject fr
Structures en béton
Partie
4
Nb partie
5
Application title
Utilization of high strength concrete for offshore applications
Keyword
NSERC
Application summary
The current research proposal is focused on the development and optimization of a new crack design criteria and minimum reinforcement suitable for high strength concrete with thick concrete cross sections, thick concrete covers, large diameter reinforcement and relatively high reinforcement ratios. Offshore structures are exposed to harsh environmental conditions, including exposure to seawater and sea spray or the structure's existence in the splash zone. An accurate estimate of the crack width and steel reinforcement can result in saving estimated to be in millions of dollars for a single platform. Most of the available expressions for crack width calculations were developed for building structures using normal strength concrete and normal concrete cover. However, offshore structures are built using high strength concrete with thick concrete sections up to 500 mm with 50 - 60 mm concrete cover. Very little research information is published on the crack analysis of high strength concrete with thick concrete section and large concrete cover used for offshore applications. The proposed numerical phase of the investigation will examine mechanisms associated with tension and flexure cracking. Other factors that affect crack width and spacing of cracks under sustained service loads will be examined. Previous important investigations conducted by the applicant on high strength concrete for offshore applications will be utilized to evaluate accurately the cracking properties of offshore structures.
High strength concrete reinforced with glass fiber reinforcement (GFRP) bars has great potential for offshore applications. The utilization of glass bars in panel-type structures requires better understanding of its cracking and tensile behaviour. The use of a non-corrosive material for concrete reinforcement will improve the structure durability and will provide great economical advantage. The current investigation will examine concrete plates reinforced with GFRP bars under uniaxial, biaxial and flexure loads. A constitutive relationship that can describe the response of the GFRP-reinforced concrete panels is being investigated.