Canada Spends Logo

Explorez notre analyse du budget 2026

Grant: Discovery Grants Program - Individual

Université de Sherbrooke

$27,000.00

Investigation of High-rise Building Ventilation for Achieving Safety and Energy Efficiency

EF 2024-25

Résumé
Canada has made a commitment to reduce greenhouse gas (GHG) emissions to 80% below 2005 levels by 2050. The buildings sector accounts for roughly 29% of energy use in Canada and almost 25% of GHG emissions. Compared with other types of buildings, high-rise buildings have a higher cooling load and are more energy intensive, which leads to periods of peak electricity demand on the utility grid in Canada during the summer. Therefore, reducing the cooling load of high-rise buildings is critical to energy savings and reduction of peak electricity demand. High-rise ventilative cooling (HVC) has proved to be an effective solution for reducing cooling load. Due to Canada's cold climate, HVC is available for a long time throughout the year, not only during the shoulder season, but also in summer. Wide application of HVC in Canada could help Canada realize its commitment in transitioning to a competitive and resilient low-carbon economy. However, fire safety is a major concern for wide HVC application. The stack effect in the large vertical spaces of high-rise buildings is beneficial for HVC but is also a great challenge for high-rise fire smoke protection. Although previous studies have focused on the issue of energy efficiency or safety of HVC, few of them have investigated these two aspects simultaneously and the associated optimum HVC design. Therefore, the conflict between high-rise ventilation and safety has not been solved, which has impeded the promotion of HVC application and become an obstacle for Canada in realizing its commitment. The overall objective of this research program is to optimize HVC design in cold climates by considering both aspects of building safety and energy efficiency. To achieve this, the research program will address the following gaps in the literature: (1) theoretical study of heat and mass transfer in high-rise ventilation and fire smoke control; (2) optimum HVC design in cold climates by considering both aspects of building safety and energy efficiency; (3) case study of high-rise ventilation for achieving safety and energy efficiency. This will be one of the first interdisciplinary research programs on building energy efficiency and safety. It will contribute to a deep understanding of heat and mass transfer in high-rise ventilation and smoke control, optimum HVC design and real HVC application in Canada. With support from the NSERC Discovery Grant, the applicant will pioneer the research and application of ventilative cooling in high-rise buildings in the world. It will promote the application of HVC across Canada and worldwide and contribute to safety, economical (energy efficiency) and environmental aspects (e.g. GHG emissions) related to high-rise buildings. It will also support the training of two PhD, two MSc, and two undergraduate students with expertise in both building safety and energy efficiency, which is highly sought after in a fast expanding area.
Programme
Discovery Grants Program - Individual
Emplacement
Quebec, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data

Tel que publié

Application id
RGPIN-2019-05824
Name nom
Qi, Dahai
Department département
Département de génie civil et de génie du bâtiment
Organization id
68
Institution établissement
Université de Sherbrooke
Province en
Québec
Province fr
Québec
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2024
Competition year année de concours
2019
Award amount
27000
Program id
RGPIN
Program name en
Discovery Grants Program - Individual
Program name fr
Programme de subventions à la découverte - individuelles
Group en
DISCOVERY RESEARCH
Group fr
RECHERCHE AXÉE SUR LA DÉCOUVERTE
Committee code
1512
Committee name en
Mechanical Engineering
Committee name fr
Génie mécanique
Area of application code
306
Area of application group en
Energy resources
Area of application group fr
Ressources d'énergie
Area of application en
Energy efficiency
Area of application fr
Efficacité énergétique
Research subject code
2107
Research subject group en
Mechanical engineering
Research subject group fr
Génie mécanique
Research subject en
Modelling, simulation and finite element methods
Research subject fr
Modélisation, simulation et méthodes des éléments finis
Field of research list names en
Not available
Field of research list names fr
Non disponible
Socioeconomic objective list names en
Not available
Socioeconomic objective list names fr
Non disponible
Application title
Investigation of High-rise Building Ventilation for Achieving Safety and Energy Efficiency
Keywords
high-rise building; ventilative cooling; natural and hybrid ventilation; mechanical ventilation; heat and mass transfer; safety; energy efficiency; building system design; thermal storage
Application summary
Canada has made a commitment to reduce greenhouse gas (GHG) emissions to 80% below 2005 levels by 2050. The buildings sector accounts for roughly 29% of energy use in Canada and almost 25% of GHG emissions. Compared with other types of buildings, high-rise buildings have a higher cooling load and are more energy intensive, which leads to periods of peak electricity demand on the utility grid in Canada during the summer. Therefore, reducing the cooling load of high-rise buildings is critical to energy savings and reduction of peak electricity demand. High-rise ventilative cooling (HVC) has proved to be an effective solution for reducing cooling load. Due to Canada's cold climate, HVC is available for a long time throughout the year, not only during the shoulder season, but also in summer. Wide application of HVC in Canada could help Canada realize its commitment in transitioning to a competitive and resilient low-carbon economy. However, fire safety is a major concern for wide HVC application. The stack effect in the large vertical spaces of high-rise buildings is beneficial for HVC but is also a great challenge for high-rise fire smoke protection. Although previous studies have focused on the issue of energy efficiency or safety of HVC, few of them have investigated these two aspects simultaneously and the associated optimum HVC design. Therefore, the conflict between high-rise ventilation and safety has not been solved, which has impeded the promotion of HVC application and become an obstacle for Canada in realizing its commitment. The overall objective of this research program is to optimize HVC design in cold climates by considering both aspects of building safety and energy efficiency. To achieve this, the research program will address the following gaps in the literature: (1) theoretical study of heat and mass transfer in high-rise ventilation and fire smoke control; (2) optimum HVC design in cold climates by considering both aspects of building safety and energy efficiency; (3) case study of high-rise ventilation for achieving safety and energy efficiency. This will be one of the first interdisciplinary research programs on building energy efficiency and safety. It will contribute to a deep understanding of heat and mass transfer in high-rise ventilation and smoke control, optimum HVC design and real HVC application in Canada. With support from the NSERC Discovery Grant, the applicant will pioneer the research and application of ventilative cooling in high-rise buildings in the world. It will promote the application of HVC across Canada and worldwide and contribute to safety, economical (energy efficiency) and environmental aspects (e.g. GHG emissions) related to high-rise buildings. It will also support the training of two PhD, two MSc, and two undergraduate students with expertise in both building safety and energy efficiency, which is highly sought after in a fast expanding area.