Grant: Discovery Grants Program - Individual
University of Saskatchewan
$18,000.00
Design and Testing of Gradient Free Magnetic Resonance Imaging
EF 2016-17
Résumé
Magnetic Resonance Imagers (MRI) are currently expensive and heavy. As a result there is limited access to MRIs for medical diagnosis because their price burdens the Canadian taxpayer and they are not portable. I propose to build on the recently developed TRansmit Array Spatial Encoding (TRASE) method that eliminates the need for complex and heavy magnetic field gradient sets and their associated power electronics. When used in conjunction with light-weight permanent magnet designs, and miniturized RF electronics, MRIs will become more affordable and portable. Applications for affordable, portable MRIs include: use in standard X-ray clinics as a first line medical imaging element and a non-ionizing alternative to X-rays; use in rural and northern Canada, remote regions in developing countries and in war zones through portable configurations that can be moved in vans and medium-sized airplanes and; use in space on the International Space Station, spaceships to Mars and on the surface of the Moon, Mars and other Solar System destinations of the future. TRASE RF coils to date have been made empirically via limited approximate methods. These RF coils exist and work but are far from optimized in terms of the spatial phase gradients they can generate. Our 1st Objective is to develop and apply engineering design equations for novel coil configurations based on the target field method. Our 2nd Objective will be to construct and test the TRASE RF coils using existing MRIs in Saskatoon and at NRC IBD. Our 3rd Objective will be to design reconstruction algorithms for TRASE data in non-uniform fields taking full account of significant noise issues. Our 4th Objective will be to apply the reconstruction algorithms to TRASE data acquired in meeting the 2nd objective with deliberate and controlled inhomogeneities applied to the magnetic field. Objectives 1 and 2 can define a complete Ph.D. project, as can pursuing Objectives 3 and 4 together. Completely mathematical projects that develop design methodology for Objective 1 or image reconstruction reconstruction algorithms for Objective 2 are also possible.
Programme
Discovery Grants Program - Individual
Bénéficiaire
Emplacement
Saskatchewan, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data
Tel que publié
Application id
311639-2012
Name nom
Sarty, GordonEric
Department département
Psychology
Organization id
16
Institution établissement
University of Saskatchewan
Province en
Saskatchewan
Province fr
Saskatchewan
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2016
Competition year année de concours
2012
Award amount
18000
Program id
RGPIN
Program name en
Discovery Grants Program - Individual
Program name fr
Programme de subventions à la découverte - individuelles
Group en
Discovery grants programs
Group fr
Programmes de subventions à la découverte
Committee code
1510
Committee name en
Electrical and Computer Engineering
Committee name fr
Génie électrique et informatique
Area of application code
518
Area of application group en
Manufacturing processes and products
Area of application group fr
Procédés et produits industriels
Area of application en
Medical equipment and apparatus
Area of application fr
Appareils et instruments médicaux
Research subject code
2107
Research subject group en
Mechanical engineering
Research subject group fr
Génie mécanique
Research subject en
Modelling, simulation and finite element methods
Research subject fr
Modélisation, simulation et méthodes des éléments finis
Partie
5
Nb partie
5
Application title
Design and Testing of Gradient Free Magnetic Resonance Imaging
Keyword
NSERC
Application summary
Magnetic Resonance Imagers (MRI) are currently expensive and heavy. As a result there is limited access to MRIs for medical diagnosis because their price burdens the Canadian taxpayer and they are not portable. I propose to build on the recently developed TRansmit Array Spatial Encoding (TRASE) method that eliminates the need for complex and heavy magnetic field gradient sets and their associated power electronics. When used in conjunction with light-weight permanent magnet designs, and miniturized RF electronics, MRIs will become more affordable and portable. Applications for affordable, portable MRIs include: use in standard X-ray clinics as a first line medical imaging element and a non-ionizing alternative to X-rays; use in rural and northern Canada, remote regions in developing countries and in war zones through portable configurations that can be moved in vans and medium-sized airplanes and; use in space on the International Space Station, spaceships to Mars and on the surface of the Moon, Mars and other Solar System destinations of the future. TRASE RF coils to date have been made empirically via limited approximate methods. These RF coils exist and work but are far from optimized in terms of the spatial phase gradients they can generate. Our 1st Objective is to develop and apply engineering design equations for novel coil configurations based on the target field method. Our 2nd Objective will be to construct and test the TRASE RF coils using existing MRIs in Saskatoon and at NRC IBD. Our 3rd Objective will be to design reconstruction algorithms for TRASE data in non-uniform fields taking full account of significant noise issues. Our 4th Objective will be to apply the reconstruction algorithms to TRASE data acquired in meeting the 2nd objective with deliberate and controlled inhomogeneities applied to the magnetic field. Objectives 1 and 2 can define a complete Ph.D. project, as can pursuing Objectives 3 and 4 together. Completely mathematical projects that develop design methodology for Objective 1 or image reconstruction reconstruction algorithms for Objective 2 are also possible.