Grant: Engage Grants Program
University of Victoria
$25,000.00
Fluid mechanical assessment of appropriate valve to conduit radio for testing prosthetic aortic valves in relevant physiological conditions using particle image velocimetry
EF 2010-11
Résumé
A first-time collaboration will be established between Dr. Peter Oshkai of the University of Victoria and
ViVitro Systems to conduct quantitative flow visualization experiments using digital particle image
velocimetry (DPIV) aimed at improving the design of ViVitro's pulse duplicator. The pulse duplicator
manufactured by ViVitro is the most widely used heart simulator in the world. The usage of this heart
simulator has been demonstrated for conducting both research and engineering testing of mechanical,
prosthestic and polymeric heart valves. A constant improvement to the design of the ViVitro pulse duplicator
system is necessitated to maintain the physiological relevance of the flow conditions generated within the
system. One such design problem and a fundamental research question is the influence of the valve to conduit
ratio on the hemodynamic parameters and flow past aortic prosthetic valves.
During the proposed study, we will collect DPIV data past a mechanical bileaflet valve and a biological
trileaflet valve with varying conduit sizes of the aortic root. The flow past these valves will be studied using
2D PIV in central and off-central planes of the valves and the influence of the ratio of aortic valve size to the
conduit size on the shear stress, turbulence characteristics, vortex shedding and flow environment will be
documented. Design recommendations for the appropriate physiologically relevant valve to conduit ratio based
on this research effort will provide for a clinically relevant test conditions within the pulse duplicator.
The project will provide significant opportunities for training of highly-qualified personnel. Several graduate
students will acquire skills that are relevant in a broad area of engineering and science through active
collaboration with industrial partners.
Programme
Engage Grants Program
Bénéficiaire
Emplacement
British Columbia, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data
Tel que publié
Application id
408138-2010
Name nom
Oshkai, Peter
Department département
Mechanical Engineering
Organization id
7
Institution établissement
University of Victoria
Province en
British Columbia
Province fr
Colombie-Britannique
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2010
Competition year année de concours
2010
Award amount
25000
Program id
EGP
Program name en
Engage Grants Program
Program name fr
Programme de subventions d'engagement partenariat
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1554
Committee name en
Pacific Internal Decision Committee
Committee name fr
Comité de décision interne pour le Pacifique
Area of application code
1102
Area of application group en
Health, education and social services
Area of application group fr
Santé publique, éducation et services sociaux
Area of application en
Biomedical engineering
Area of application fr
Génie biomédical
Research subject code
2200
Research subject group en
Fluid mechanics
Research subject group fr
Mécanique des fluides
Research subject en
Fluid mechanics
Research subject fr
Mécanique des fluides
Partie
1
Nb partie
1
Application title
Fluid mechanical assessment of appropriate valve to conduit radio for testing prosthetic aortic valves in relevant physiological conditions using particle image velocimetry
Keyword
NSERC
Application summary
A first-time collaboration will be established between Dr. Peter Oshkai of the University of Victoria and
ViVitro Systems to conduct quantitative flow visualization experiments using digital particle image
velocimetry (DPIV) aimed at improving the design of ViVitro's pulse duplicator. The pulse duplicator
manufactured by ViVitro is the most widely used heart simulator in the world. The usage of this heart
simulator has been demonstrated for conducting both research and engineering testing of mechanical,
prosthestic and polymeric heart valves. A constant improvement to the design of the ViVitro pulse duplicator
system is necessitated to maintain the physiological relevance of the flow conditions generated within the
system. One such design problem and a fundamental research question is the influence of the valve to conduit
ratio on the hemodynamic parameters and flow past aortic prosthetic valves.
During the proposed study, we will collect DPIV data past a mechanical bileaflet valve and a biological
trileaflet valve with varying conduit sizes of the aortic root. The flow past these valves will be studied using
2D PIV in central and off-central planes of the valves and the influence of the ratio of aortic valve size to the
conduit size on the shear stress, turbulence characteristics, vortex shedding and flow environment will be
documented. Design recommendations for the appropriate physiologically relevant valve to conduit ratio based
on this research effort will provide for a clinically relevant test conditions within the pulse duplicator.
The project will provide significant opportunities for training of highly-qualified personnel. Several graduate
students will acquire skills that are relevant in a broad area of engineering and science through active
collaboration with industrial partners.