Canada Spends Logo

Explorez notre analyse du budget 2026

Grant: Engage Grants Program

Ryerson University

$25,000.00

Performance Evaluation and Comparison Between Conventional U-Tube and New Kelix Tube-in-Tube Ground Heat Exchangers and Between Regular Grout and Supergrout

EF 2012-13

Résumé
The geothermal heat pump, also known as the ground source heat pump (GSHP), is a highly efficient renewable energy technology that is gaining wide acceptance for both residential and commercial buildings. GSHPs are used for space heating and cooling, as well as water heating. The technology relies on the fact that the Earth (beneath the surface) remains at a relatively constant temperature throughout the year, warmer than the air above it during the winter and cooler in the summer. The GSHP takes advantage of this by transferring heat stored in the Earth or in ground water into a building during the winter, and transferring it out of the building and back into the ground during the summer. Using the Earth as a heat source/sink, a series of pipes, commonly called a ""loop,"" is buried in the ground near the building to be conditioned. It usually circulates an antifreeze solution fluid that absorbs heat from, or relinquishes heat to, the surrounding soil, depending on whether the fluid is colder or warmer than the soil. If a ground heat exchanger (GHE) can better transfer heat between the heat pump and the ground, the overall performance of the GSHP would be higher. There is a new design of tube-in-tube GHE. The performance of the GHE has been claimed by Felix Heat Transfer Systems (the company which sells the GHE) to be double to triple that of the conventional U-tube GHE without any actual test or verification. In order to utilize this latest advancements in geothermal GHE, McClymont & Rak Engineers (MCR) Inc. has recently installed two different types of vertical loop designs in a house at ECOFARM in Caledon East, Ontario, for comparison of effectiveness and performance, a first in this industry. The project will lead to a clear comparison of the performance between the conventional U-tube and Kelix GHEs, as well as between regular grout and supergrout, and will enable MCR and GSHP industry to offer high-performance and affordable GSHP systems. In addition, the results can also be used to verify and improve existing ground-loop design tools and software for the Kelix GHE.
Programme
Engage Grants Program
Bénéficiaire
Emplacement
Ontario, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data

Tel que publié

Application id
445979-2012
Name nom
Leong, WeyHerng
Department département
Mechanical and Industrial Engineering
Organization id
43
Institution établissement
Ryerson University
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2012
Competition year année de concours
2012
Award amount
25000
Program id
EGP
Program name en
Engage Grants Program
Program name fr
Programme de subventions d'engagement partenariat
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1553
Committee name en
Ontario Internal Decision Committee
Committee name fr
Comité de décision interne pour l'Ontario
Area of application code
303
Area of application group en
Energy resources
Area of application group fr
Ressources d'énergie
Area of application en
Alternative energy resources
Area of application fr
Autres ressources d'énergie
Research subject code
2109
Research subject group en
Mechanical engineering
Research subject group fr
Génie mécanique
Research subject en
Mechanical systems and instrumentation
Research subject fr
Instrumentation et systèmes mécaniques
Partie
1
Nb partie
1
Application title
Performance Evaluation and Comparison Between Conventional U-Tube and New Kelix Tube-in-Tube Ground Heat Exchangers and Between Regular Grout and Supergrout
Keyword
NSERC
Application summary
The geothermal heat pump, also known as the ground source heat pump (GSHP), is a highly efficient renewable energy technology that is gaining wide acceptance for both residential and commercial buildings. GSHPs are used for space heating and cooling, as well as water heating. The technology relies on the fact that the Earth (beneath the surface) remains at a relatively constant temperature throughout the year, warmer than the air above it during the winter and cooler in the summer. The GSHP takes advantage of this by transferring heat stored in the Earth or in ground water into a building during the winter, and transferring it out of the building and back into the ground during the summer. Using the Earth as a heat source/sink, a series of pipes, commonly called a ""loop,"" is buried in the ground near the building to be conditioned. It usually circulates an antifreeze solution fluid that absorbs heat from, or relinquishes heat to, the surrounding soil, depending on whether the fluid is colder or warmer than the soil. If a ground heat exchanger (GHE) can better transfer heat between the heat pump and the ground, the overall performance of the GSHP would be higher. There is a new design of tube-in-tube GHE. The performance of the GHE has been claimed by Felix Heat Transfer Systems (the company which sells the GHE) to be double to triple that of the conventional U-tube GHE without any actual test or verification. In order to utilize this latest advancements in geothermal GHE, McClymont & Rak Engineers (MCR) Inc. has recently installed two different types of vertical loop designs in a house at ECOFARM in Caledon East, Ontario, for comparison of effectiveness and performance, a first in this industry. The project will lead to a clear comparison of the performance between the conventional U-tube and Kelix GHEs, as well as between regular grout and supergrout, and will enable MCR and GSHP industry to offer high-performance and affordable GSHP systems. In addition, the results can also be used to verify and improve existing ground-loop design tools and software for the Kelix GHE.