Canada Spends Logo

Explorez notre analyse du budget 2026

Grant: Collaborative Research and Development Grants

University of Manitoba

$17,500.00

An investigation of space charge profile on the flashover characteristics of fiberglass reinforced plastic (FRP) tools under DC conditions

EF 2017-18

Résumé
Live line maintenance, i.e. performing maintenance while power transmission lines are energized, is an efficient, economical method to ensure the reliability of electric power systems. However, live line work in Manitoba was suspended for 10 years as a result of two accidents at Manitoba Hydro, and it still has not resumed at the required capacity. In this work, an investigation into the effects of the factors associated with live line work on Direct Current (DC) transmission lines will be carried out and how the DC characteristics affect the performance of the tools used by live line workers in industry. There is suspicion that the characteristics of DC voltage may result in more hazardous working conditions than those experienced when working on the more common Alternating Current (AC). Presently, industry standards for providing worker safety do not consider the unique characteristics associated with working on DC, and are based on AC test results. The results of this research will help to ensure the safety of workers during live line maintenance on DC transmission lines so that live line work can continue to be carried out, thereby guaranteeing the economic benefits associated with this practice. Further, the ability to perform live line maintenance will help utilities, such as Manitoba Hydro, the industrial partner of this project, to avoid revenue losses due to planned outages as well as the performance of preventative maintenance.
Programme
Collaborative Research and Development Grants
Emplacement
Manitoba, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data

Tel que publié

Application id
489091-2015
Name nom
Kordi, Behzad
Department département
Electrical and Computer Engineering
Organization id
19
Institution établissement
University of Manitoba
Province en
Manitoba
Province fr
Manitoba
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2017
Competition year année de concours
2015
Award amount
17500
Program id
CRDPJ
Program name en
Collaborative Research and Development Grants
Program name fr
Subventions de recherche et développement coopérative
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
96
Committee name en
RPP Internal Decision Cttee
Committee name fr
Cté de décision interne - PPR
Area of application code
304
Area of application group en
Energy resources
Area of application group fr
Ressources d'énergie
Area of application en
Electrical energy
Area of application fr
Énergie électrique
Research subject code
2500
Research subject group en
Electrical and electronic engineering
Research subject group fr
Génie électrique et électronique
Research subject en
Electrical and electronic engineering
Research subject fr
Génie électrique et électronique
Partie
2
Nb partie
2
Application title
An investigation of space charge profile on the flashover characteristics of fiberglass reinforced plastic (FRP) tools under DC conditions
Keyword
NSERC
Application summary
Live line maintenance, i.e. performing maintenance while power transmission lines are energized, is an efficient, economical method to ensure the reliability of electric power systems. However, live line work in Manitoba was suspended for 10 years as a result of two accidents at Manitoba Hydro, and it still has not resumed at the required capacity. In this work, an investigation into the effects of the factors associated with live line work on Direct Current (DC) transmission lines will be carried out and how the DC characteristics affect the performance of the tools used by live line workers in industry. There is suspicion that the characteristics of DC voltage may result in more hazardous working conditions than those experienced when working on the more common Alternating Current (AC). Presently, industry standards for providing worker safety do not consider the unique characteristics associated with working on DC, and are based on AC test results. The results of this research will help to ensure the safety of workers during live line maintenance on DC transmission lines so that live line work can continue to be carried out, thereby guaranteeing the economic benefits associated with this practice. Further, the ability to perform live line maintenance will help utilities, such as Manitoba Hydro, the industrial partner of this project, to avoid revenue losses due to planned outages as well as the performance of preventative maintenance.