Grant: Doctoral Award - Frederick Banting and Charles Best Canada Graduate Scholarships
University of Toronto
$105,000.00
Design and Testing of a Novel Posterior Spinal Fusion Device Providing a Less-Invasive and Faster Alternative to Current Techniques.
EF 2008-09
Résumé
Spinal Fusion is used to treat spinal instabilities caused by trauma, arthritis or cancer. In 2001, almost 300,000 spinal fusion operations were performed in the US alone. Current techniques for posterior spinal fusion are predominated by the technically demanding pedicle screw-rod constructs. The delicate nature of the procedure includes a risk of neurological/vascular damage leading to large surgical exposures and extended anesthetic time. We hypothesize that a new posterior spinal fusion system can be created which is less invasive, quicker and easier to install leading to substantially less patient risk while maintaining the structural integrity needed for a strong fusion.
This project aims to develop and evaluate a novel posterior spinal fusion system. Our proposed device is a single/multi-level posterior fusion system utilizing the spinous processes and laminae (most posterior aspects of the spine) as the point of anchorage while accommodating the varying spinal curvatures of the patient population. The novelty of the device (patent filed Apr. 14, 2008) lies in its expandability, ease of installation and removal, and the potential for accelerating/monitoring bony fusion. The unique design and installation method will provide a less invasive alternative which lowers neurological/vascular risk while simultaneously decreasing needed surgical exposure and anesthetic time.
Device prototyping has commenced allowing for modular verification of the implants mechanical integrity. Upon completion, we will move to industry standard in vitro testing of the system both with simulated spinal motion segments and cadaveric equivalents. The ultimate goal of this testing is to bring a well studied and proven design to the public where its innovative methods can positively impact the health care system. The potential benefits of the system will reduce patient risk, surgical exposure and anesthetic time to lower both surgical wait times and post-operative hospital stays.
Programme
Doctoral Award - Frederick Banting and Charles Best Canada Graduate Scholarships
Bénéficiaire
Emplacement
Ontario, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
CIHR Funding Decisions Database
Tel que publié
Id
184621
Name
Singh Devin A
Region
Ontario
Country
Canada
Orgtype
Institution Paid; Research Institution
Instname2
Musculoskeletal Health and Arthritis
Theme2
Biomedical
Prcname2
Doctoral Research Awards - A
Projecttitle
Design and Testing of a Novel Posterior Spinal Fusion Device Providing a Less-Invasive and Faster Alternative to Current Techniques.
Programtype2
Studentship Programs
Orgnameinp2
University of Toronto
Cihramount2
$105,000
Cihrequipment2
$0
Programname2
Doctoral Award - Frederick Banting and Charles Best Canada Graduate Scholarships
Keyworddelim
Arthritis; Biomechanics; Commercialization; Image Analysis; Orthopaedic; Spinal Fusion; Trauma; Tumour
Abstract
Spinal Fusion is used to treat spinal instabilities caused by trauma, arthritis or cancer. In 2001, almost 300,000 spinal fusion operations were performed in the US alone. Current techniques for posterior spinal fusion are predominated by the technically demanding pedicle screw-rod constructs. The delicate nature of the procedure includes a risk of neurological/vascular damage leading to large surgical exposures and extended anesthetic time. We hypothesize that a new posterior spinal fusion system can be created which is less invasive, quicker and easier to install leading to substantially less patient risk while maintaining the structural integrity needed for a strong fusion.
This project aims to develop and evaluate a novel posterior spinal fusion system. Our proposed device is a single/multi-level posterior fusion system utilizing the spinous processes and laminae (most posterior aspects of the spine) as the point of anchorage while accommodating the varying spinal curvatures of the patient population. The novelty of the device (patent filed Apr. 14, 2008) lies in its expandability, ease of installation and removal, and the potential for accelerating/monitoring bony fusion. The unique design and installation method will provide a less invasive alternative which lowers neurological/vascular risk while simultaneously decreasing needed surgical exposure and anesthetic time.
Device prototyping has commenced allowing for modular verification of the implants mechanical integrity. Upon completion, we will move to industry standard in vitro testing of the system both with simulated spinal motion segments and cadaveric equivalents. The ultimate goal of this testing is to bring a well studied and proven design to the public where its innovative methods can positively impact the health care system. The potential benefits of the system will reduce patient risk, surgical exposure and anesthetic time to lower both surgical wait times and post-operative hospital stays.
Competitiondate
200810
Approvedterm2
3 yrs 0 mth
Pinamesdelim
Singh, Devin A
Approvedterm
3 ans 0 mois
Cihrcontribution2
~ $105,000~ $0~