Grant: Proof of Principle Program - Phase I
University of British Columbia
$158,740.00
Certifiably safe closed-loop control of anesthesia
EF 2014-15
Résumé
Inducing and maintaining total intravenous anesthesia requires the continuous infusion of at least two carefully titrated drugs; one to suppress consciousness and another to suppress response to pain. Typically these drugs are infused by syringe pumps, manually programmed to deliver them at a fixed rate, based on the patient's body weight. However, response to these drugs varies between patients and situations (e.g., different types of surgery, extreme bleeding, prolonged infusion). Anesthesiologists manually adjust dosing to account for this variability based on feedback from physiological sensors. Closed-loop control systems, designed by control engineers, can regulate and personalize drug infusion by using feedback from the patient's response. By optimizing drug infusion for each individual and situation, these systems will improve patient safety during anesthesia, and will lead to faster recovery times and lower complication rates. In this project, our unique interdisciplinary team of anesthetists and control engineers, seeks to finalize the design of a certifiably safe closed-loop control system for anesthesia.
Programme
Proof of Principle Program - Phase I
Bénéficiaire
Emplacement
British Columbia, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
CIHR Funding Decisions Database
Tel que publié
Id
325024
Name
Dumont Guy A
Region
British Columbia
Country
Canada
Orgtype
Institution Paid; Research Institution
Instname2
Circulatory and Respiratory Health
Theme2
Clinical
Prcname2
Proof of Principle
Projecttitle
Certifiably safe closed-loop control of anesthesia
Programtype2
Operating Grants
Orgnameinp2
University of British Columbia
Cihramount2
$158,740
Cihrequipment2
$0
Programname2
Proof of Principle Program - Phase I
Keyworddelim
Biomedical Research-Multidisciplinary
Abstract
Inducing and maintaining total intravenous anesthesia requires the continuous infusion of at least two carefully titrated drugs; one to suppress consciousness and another to suppress response to pain. Typically these drugs are infused by syringe pumps, manually programmed to deliver them at a fixed rate, based on the patient's body weight. However, response to these drugs varies between patients and situations (e.g., different types of surgery, extreme bleeding, prolonged infusion). Anesthesiologists manually adjust dosing to account for this variability based on feedback from physiological sensors. Closed-loop control systems, designed by control engineers, can regulate and personalize drug infusion by using feedback from the patient's response. By optimizing drug infusion for each individual and situation, these systems will improve patient safety during anesthesia, and will lead to faster recovery times and lower complication rates. In this project, our unique interdisciplinary team of anesthetists and control engineers, seeks to finalize the design of a certifiably safe closed-loop control system for anesthesia.
Competitiondate
201502
Approvedterm2
1 yr 0 mth
Pinamesdelim
Dumont, Guy A
Approvedterm
1 an 0 mois
Cihrcontribution2
~ $158,740~ $0~