Grant: Discovery Grants Program - Individual
Université de Montréal
$28,000.00
Dual-Energy Cone-Beam CT as an online quantitative imaging modality for adaptive radiotherapy
EF 2023-24
Résumé
The purpose of this research program is to explore potential applications of dual-energy cone-beam computed tomography (DE-CBCT) in the context of adaptive radiotherapy. The increasing roles of automation and treatment personalization in radiation oncology underline the need for novel quantitative on-board imaging solutions. External beam radiation therapy consists of delivering a high dose of radiation to cancerous cells while sparing the surrounding organs at risk. Radiotherapy treatment plans are created using a computed tomography (CT) of the patient, from which optimal properties of radiation beams (energy, direction, intensity modulation and collimation) are determined. Conventional treatments are the typically delivered over approximately thirty daily sessions, giving the time to the healthy cells to repair sublethal damages induced by the radiation while delivering a therapeutic cumulative radiation dose to the tumor. While biologically favorable, this approach loses its efficacy if the patient's anatomy changes during the treatment, as the radiation beams are then at risk to miss their target. In such cases, adaptive radiotherapy (ART) approaches can be used to modify the initial treatment plan to better reflect the evolution of the patient's anatomy. Current online ART methods (i.e. performed immediately after setting up the patient for their treatment) are currently only performed on dedicated and expensive equipments (e.g. MRI-linacs). This research programs explores an alternative imaging modality for online adaptive radiotherapy, DE-CBCT. This research program will focus on three specific aims. The first is on the development of a Monte Carlo environment to explore optimal DE-CBCT configurations. Using Monte Carlo simulations with the EGSnrc toolkit, we will model several DE-CBCT configurations that can be implemented on conventional radiotherapy equipment with none to minimal hardware alteration. The second is to investigate DE-CBCT image processing methods to derive physical parameters needed for proton therapy dose calculations in real-time. Reference methods previously validated in the context of fan-beam DECT will be adapted to the context of DE-CBCT, with an emphasis on the specific challenges associated with the calibration procedure for CBCT systems. Finally, we will investigate the impact of DE-CBCT on the quality and consistency of imaging biomarkers derived from longitudinal images acquired during radiation therapy treatment courses.
Programme
Discovery Grants Program - Individual
Bénéficiaire
Emplacement
Quebec, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data
Tel que publié
Application id
RGPIN-2023-03952
Name nom
Lalonde, Arthur
Department département
Radiation Oncology
Organization id
63
Institution établissement
Université de Montréal
Province en
Québec
Province fr
Québec
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2023
Competition year année de concours
2023
Award amount
28000
Program id
RGPIN
Program name en
Discovery Grants Program - Individual
Program name fr
Programme de subventions à la découverte - individuelles
Group en
DISCOVERY RESEARCH
Group fr
RECHERCHE AXÉE SUR LA DÉCOUVERTE
Committee code
1505
Committee name en
Physics
Committee name fr
Physique
Area of application code
518
Area of application group en
Manufacturing processes and products
Area of application group fr
Procédés et produits industriels
Area of application en
Medical equipment and apparatus
Area of application fr
Appareils et instruments médicaux
Research subject code
9999
Research subject group en
Not available
Research subject group fr
Not available
Research subject en
Non disponible
Research subject fr
Non disponible
Application title
Dual-Energy Cone-Beam CT as an online quantitative imaging modality for adaptive radiotherapy
Keyword
Adaptive Radiotherapy; Artificial Intelligence; Cone-beam Computed Tomography; Dual-energy Computed Tomography; Proton Therapy; Radiation Oncology
Application summary
The purpose of this research program is to explore potential applications of dual-energy cone-beam computed tomography (DE-CBCT) in the context of adaptive radiotherapy. The increasing roles of automation and treatment personalization in radiation oncology underline the need for novel quantitative on-board imaging solutions. External beam radiation therapy consists of delivering a high dose of radiation to cancerous cells while sparing the surrounding organs at risk. Radiotherapy treatment plans are created using a computed tomography (CT) of the patient, from which optimal properties of radiation beams (energy, direction, intensity modulation and collimation) are determined. Conventional treatments are the typically delivered over approximately thirty daily sessions, giving the time to the healthy cells to repair sublethal damages induced by the radiation while delivering a therapeutic cumulative radiation dose to the tumor. While biologically favorable, this approach loses its efficacy if the patient's anatomy changes during the treatment, as the radiation beams are then at risk to miss their target. In such cases, adaptive radiotherapy (ART) approaches can be used to modify the initial treatment plan to better reflect the evolution of the patient's anatomy. Current online ART methods (i.e. performed immediately after setting up the patient for their treatment) are currently only performed on dedicated and expensive equipments (e.g. MRI-linacs). This research programs explores an alternative imaging modality for online adaptive radiotherapy, DE-CBCT. This research program will focus on three specific aims. The first is on the development of a Monte Carlo environment to explore optimal DE-CBCT configurations. Using Monte Carlo simulations with the EGSnrc toolkit, we will model several DE-CBCT configurations that can be implemented on conventional radiotherapy equipment with none to minimal hardware alteration. The second is to investigate DE-CBCT image processing methods to derive physical parameters needed for proton therapy dose calculations in real-time. Reference methods previously validated in the context of fan-beam DECT will be adapted to the context of DE-CBCT, with an emphasis on the specific challenges associated with the calibration procedure for CBCT systems. Finally, we will investigate the impact of DE-CBCT on the quality and consistency of imaging biomarkers derived from longitudinal images acquired during radiation therapy treatment courses.