Grant: Project Grant
Toronto Metropolitan University
$501,076.00
Design Revisions and Validations of a Catheter Steering and Navigation System For Peripheral Endovascular Revascularization
EF 2023-24
Résumé
Conventional catheter-based minimally invasive cardiovascular interventions face two fundamental challenges: the first is associated with the catheter's limited steerability and support due to its long length, high flexibility, engagement with the anatomy, and its remote manipulation from outside the patient body; the second is associated with poor visualization as x-ray imaging fails to provide 3D anatomical visualization. These constraints hinder accurate and effective catheter navigation, ultimately contributing to long procedure times, high failure, and complication rates. To address this problem, we have developed a radically different steerable catheter. It consists of an expandable frame, which is initially constrained within an outer sheath until it is brought to the vicinity of the target anatomy. Then the frame is expanded and anchors to the anatomy of interest. Once expanded, the frame can be mechanically leveraged, and it allows for local manipulation and tracking of an internal catheter relative to this frame. This platform technology provides a passive and inexpensive solution that overcomes the intrinsic limitations of conventional devices. This solution offers localized manipulation and control, accurate tracking, and reliable navigation of the catheter relative to the anatomy of interest rather than a random trial and error approach that exists with remote manipulation of conventional devices. With the goal of commercializing this technology for an initial target application of peripheral endovascular revascularization, the proposed activities of this application entail finalizing design revisions of this technology and performing preclinical and clinical studies. The preclinical and clinical study results will be a major inflection point that will lead to further interest from end-users, private investors, and potential industrial partners to allow for the commercialization of the technology at a global scale.
Programme
Project Grant
Bénéficiaire
Emplacement
Ontario, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
CIHR Funding Decisions Database
Tel que publié
Id
500011
Name
Tavallaei Mohammad A
Region
Ontario
Country
Canada
Orgtype
Institution Paid; Research Institution
Instname2
Circulatory and Respiratory Health
Theme2
Biomedical
Prcname2
Commercialization
Projecttitle
Design Revisions and Validations of a Catheter Steering and Navigation System For Peripheral Endovascular Revascularization
Programtype2
Operating Grants
Orgnameinp2
Toronto Metropolitan University
Cihramount2
$501,076
Cihrequipment2
$0
Programname2
Project Grant
Keyworddelim
Catheter Navigation; Image Guided Therapy; Revascularization; Steerable Catheter
Abstract
Conventional catheter-based minimally invasive cardiovascular interventions face two fundamental challenges: the first is associated with the catheter's limited steerability and support due to its long length, high flexibility, engagement with the anatomy, and its remote manipulation from outside the patient body; the second is associated with poor visualization as x-ray imaging fails to provide 3D anatomical visualization. These constraints hinder accurate and effective catheter navigation, ultimately contributing to long procedure times, high failure, and complication rates. To address this problem, we have developed a radically different steerable catheter. It consists of an expandable frame, which is initially constrained within an outer sheath until it is brought to the vicinity of the target anatomy. Then the frame is expanded and anchors to the anatomy of interest. Once expanded, the frame can be mechanically leveraged, and it allows for local manipulation and tracking of an internal catheter relative to this frame. This platform technology provides a passive and inexpensive solution that overcomes the intrinsic limitations of conventional devices. This solution offers localized manipulation and control, accurate tracking, and reliable navigation of the catheter relative to the anatomy of interest rather than a random trial and error approach that exists with remote manipulation of conventional devices. With the goal of commercializing this technology for an initial target application of peripheral endovascular revascularization, the proposed activities of this application entail finalizing design revisions of this technology and performing preclinical and clinical studies. The preclinical and clinical study results will be a major inflection point that will lead to further interest from end-users, private investors, and potential industrial partners to allow for the commercialization of the technology at a global scale.
Competitiondate
202403
Approvedterm2
3 yrs 0 mth
Pinamesdelim
Tavallaei, Mohammad A
Approvedterm
3 ans 0 mois
Cihrcontribution2