Canada Spends Logo

Explorez notre analyse du budget 2026

Grant: Discovery Grants Program - Individual

University of Windsor

$28,000.00

Advanced Micromachined Ultrasonic Transducers for High Performance Medical Imaging Systems

EF 2019-20

Résumé
Breast cancer is a leading cause of death in women that is often undetected and underdiagnosed, contributing to the significant death rate of more than 21% of all female cancer deaths [Canadian Cancer Society Statistics 2017]. Amongst all diagnostic techniques, magnetic resonance imaging provides a more accurate estimate of tumor size. However, its cost, poor accessibility and inapplicable nature for patients with some implanted medical devices restrain its usage. Therefore, there is a momentous need to develop an accurate, safe and low-cost system that makes the examination procedure more frequently available to a larger portion of women across the world. ***Advance ultrasound imaging systems are emerging as essential and practical tools in routine clinical practices due to their nonionizing and noninvasive nature and lower cost. The crucial component of these ultrasound systems is the ultrasonic transducer and a promising candidate technology to advance state-of-the-art ultrasound imaging is capacitive micromachined ultrasonic transducer, CMUT. ***These transducers bring advanced microelectromechanical system (MEMS) fabrication technology to the field of ultrasound imaging and overcome the fabrication limitations of many bulk piezoelectric transducers. They offer batch production, which reduces the cost, tight parameter specification, wide bandwidth and achievable CMOS integration. However, they fall short particularly with output acoustic pressure, performance compromise between transmitting and receiving modes and their demand for high bias voltage. ***In this research program and in contrast with traditional MEMS transducers, the focus is on an innovative micromachined transducer configuration where more than one deflectable plate is employed in the CMUT cell structure. The unifying theme is to exploit the unique opportunity given by contribution of two or more vibrating membranes in transmitting and receiving ultrasonic signals. To reach this goal comprehensive analytical and numerical model will be developed; physical properties of multiple vibrating plates will be optimized; various fabricating techniques as well as packaging will be assessed; prototype devices will be fabricated; array configurations will be probed and electrical and acoustic properties of these transducers will be analyzed. This research program is designed to address many of unique concerns of conventional CMUTs including providing dynamic switching between different modes, enhancing output pressure and lowering the driving voltage.***The wide implication of this program offers many attractive applications including diagnostic imaging and therapeutic applications that provide enhanced health care to Canadian. Training of highly qualified personnel with a diverse set of skills is the essential component of this research proposal that will benefit Canadian private and public sectors.
Programme
Discovery Grants Program - Individual
Bénéficiaire
Emplacement
Ontario, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data

Tel que publié

Application id
RGPIN-2018-03998
Name nom
Emadi, Arezoo
Department département
Electrical and Computer Engineering
Organization id
37
Institution établissement
University of Windsor
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2019
Competition year année de concours
2018
Award amount
28000
Program id
RGPIN
Program name en
Discovery Grants Program - Individual
Program name fr
Programme de subventions à la découverte - individuelles
Group en
DISCOVERY RESEARCH
Group fr
RECHERCHE AXÉE SUR LA DÉCOUVERTE
Committee code
1510
Committee name en
Electrical and Computer Engineering
Committee name fr
Génie électrique et informatique
Area of application code
1102
Area of application group en
Health, education and social services
Area of application group fr
Santé publique, éducation et services sociaux
Area of application en
Biomedical engineering
Area of application fr
Génie biomédical
Research subject code
2519
Research subject group en
Electrical and electronic engineering
Research subject group fr
Génie électrique et électronique
Research subject en
Microelectronics
Research subject fr
Microélectronique
Installment
inst:2 - 5
Partie
2
Nb partie
5
Application title
Advanced Micromachined Ultrasonic Transducers for High Performance Medical Imaging Systems
Keyword
NSERC
Application summary
Breast cancer is a leading cause of death in women that is often undetected and underdiagnosed, contributing to the significant death rate of more than 21% of all female cancer deaths [Canadian Cancer Society Statistics 2017]. Amongst all diagnostic techniques, magnetic resonance imaging provides a more accurate estimate of tumor size. However, its cost, poor accessibility and inapplicable nature for patients with some implanted medical devices restrain its usage. Therefore, there is a momentous need to develop an accurate, safe and low-cost system that makes the examination procedure more frequently available to a larger portion of women across the world. ***Advance ultrasound imaging systems are emerging as essential and practical tools in routine clinical practices due to their nonionizing and noninvasive nature and lower cost. The crucial component of these ultrasound systems is the ultrasonic transducer and a promising candidate technology to advance state-of-the-art ultrasound imaging is capacitive micromachined ultrasonic transducer, CMUT. ***These transducers bring advanced microelectromechanical system (MEMS) fabrication technology to the field of ultrasound imaging and overcome the fabrication limitations of many bulk piezoelectric transducers. They offer batch production, which reduces the cost, tight parameter specification, wide bandwidth and achievable CMOS integration. However, they fall short particularly with output acoustic pressure, performance compromise between transmitting and receiving modes and their demand for high bias voltage. ***In this research program and in contrast with traditional MEMS transducers, the focus is on an innovative micromachined transducer configuration where more than one deflectable plate is employed in the CMUT cell structure. The unifying theme is to exploit the unique opportunity given by contribution of two or more vibrating membranes in transmitting and receiving ultrasonic signals. To reach this goal comprehensive analytical and numerical model will be developed; physical properties of multiple vibrating plates will be optimized; various fabricating techniques as well as packaging will be assessed; prototype devices will be fabricated; array configurations will be probed and electrical and acoustic properties of these transducers will be analyzed. This research program is designed to address many of unique concerns of conventional CMUTs including providing dynamic switching between different modes, enhancing output pressure and lowering the driving voltage.***The wide implication of this program offers many attractive applications including diagnostic imaging and therapeutic applications that provide enhanced health care to Canadian. Training of highly qualified personnel with a diverse set of skills is the essential component of this research proposal that will benefit Canadian private and public sectors.