Canada Spends Logo

Explorez notre analyse du budget 2026

Grant: Discovery Grants Program - Individual

University of Alberta

$56,000.00

Instrumentation and Methods for Magnetic Resonance Imaging

EF 2024-25

Résumé
This research program will improve magnetic resonance imaging (MRI) technology and enhance not only the imaging performance (e.g., signal-to-noise ratio (SNR), resolution, speed) but also safety and patient experience. These goals depend greatly on the radio frequency (RF) signal detectors or "coils", which are placed around the patient and used for signal excitation and for signal reception. The first core goal of this research program is to improve MRI in the torso and abdomen by taking advantage of better imaging performance that is possible with MRI magnetic field strengths (measured in tesla or T) that are higher than those used clinically (1.5 and 3.0 T). While lower than the 7 T available at some research centres, the 4.7 T at the University of Alberta offers the unique opportunity to do body imaging (never done before) at this intermediate field strength which we believe is the "sweet spot". Higher fields cause patchy bright and dark regions in the images because of the short RF wavelength. Despite the high SNR achievable in the bright regions, the patchiness compromises image quality and precludes clinical use because the dark regions could conceal disease invisible to a radiologist. At 7 T, patchiness is very prominent and impossible to eliminate over a large enough field of view without the most advanced methods, which are technically challenging and require expert supervision to work reliably. Indeed, the US FDA has cleared 7 T for clinical use only on the head and limbs. We will build the coils needed for body imaging at 4.7 T and compare image quality with that at 3 and 7 T. The second core goal of this research program is to develop enabling innovations and advanced instrumentation, beginning with a reliable detector for specific absorption rate (SAR) calibration. Signal excitation uses RF pulses which inevitably heat the patient's body. Therefore MRI scanners need real-time SAR monitoring to ensure the heating does not cause injury. Devices that emit ionizing radiation (e.g., x-ray machines) are calibrated using standardized procedures, but the SAR monitoring system is calibrated by each manufacturer using proprietary methods. We will develop a robust "SAR detector" and method to calibrate the SAR monitor, to allow a standardized comparison of SAR levels from different scanners. We will also develop technology to enable truly ergonomic "wearable" coils, instead of the bulky, intimidating cages currently in use. One component needed to achieve this is a better RF switch to make sensitive receive-only coils immune to the transmit pulses. The two types of switch in current use have problems such as generating heat or low reliability, and they both require control wires that complicate the cabling. We will realise a switch without these limitations. Finally, we will adapt the lightweight coils we designed for linac-MR radiation therapy machines to PET-MR scanners which also require coils that are essentially transparent to x-rays.
Programme
Discovery Grants Program - Individual
Bénéficiaire
Emplacement
Alberta, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data

Tel que publié

Application id
RGPIN-2020-04363
Name nom
De Zanche, Nicola
Department département
Oncology - Oncology
Organization id
9
Institution établissement
University of Alberta
Province en
Alberta
Province fr
Alberta
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2024
Competition year année de concours
2020
Award amount
56000
Program id
RGPIN
Program name en
Discovery Grants Program - Individual
Program name fr
Programme de subventions à la découverte - individuelles
Group en
DISCOVERY RESEARCH
Group fr
RECHERCHE AXÉE SUR LA DÉCOUVERTE
Committee code
1505
Committee name en
Physics
Committee name fr
Physique
Area of application code
518
Area of application group en
Manufacturing processes and products
Area of application group fr
Procédés et produits industriels
Area of application en
Medical equipment and apparatus
Area of application fr
Appareils et instruments médicaux
Research subject code
1901
Research subject group en
Biomedical engineering
Research subject group fr
Génie biomédical
Research subject en
Biomedical technology
Research subject fr
Technologie biomédicale
Field of research list names en
Not available
Field of research list names fr
Non disponible
Socioeconomic objective list names en
Not available
Socioeconomic objective list names fr
Non disponible
Application title
Instrumentation and Methods for Magnetic Resonance Imaging
Keywords
magnetic resonance imaging (mri); high-field mri; radio frequency electronics; radio frequency detector coils; coil arrays; signal-to-noise ratio; specific absorption rate; body imaging; pet-mr; lightweight coils
Application summary
This research program will improve magnetic resonance imaging (MRI) technology and enhance not only the imaging performance (e.g., signal-to-noise ratio (SNR), resolution, speed) but also safety and patient experience. These goals depend greatly on the radio frequency (RF) signal detectors or "coils", which are placed around the patient and used for signal excitation and for signal reception. The first core goal of this research program is to improve MRI in the torso and abdomen by taking advantage of better imaging performance that is possible with MRI magnetic field strengths (measured in tesla or T) that are higher than those used clinically (1.5 and 3.0 T). While lower than the 7 T available at some research centres, the 4.7 T at the University of Alberta offers the unique opportunity to do body imaging (never done before) at this intermediate field strength which we believe is the "sweet spot". Higher fields cause patchy bright and dark regions in the images because of the short RF wavelength. Despite the high SNR achievable in the bright regions, the patchiness compromises image quality and precludes clinical use because the dark regions could conceal disease invisible to a radiologist. At 7 T, patchiness is very prominent and impossible to eliminate over a large enough field of view without the most advanced methods, which are technically challenging and require expert supervision to work reliably. Indeed, the US FDA has cleared 7 T for clinical use only on the head and limbs. We will build the coils needed for body imaging at 4.7 T and compare image quality with that at 3 and 7 T. The second core goal of this research program is to develop enabling innovations and advanced instrumentation, beginning with a reliable detector for specific absorption rate (SAR) calibration. Signal excitation uses RF pulses which inevitably heat the patient's body. Therefore MRI scanners need real-time SAR monitoring to ensure the heating does not cause injury. Devices that emit ionizing radiation (e.g., x-ray machines) are calibrated using standardized procedures, but the SAR monitoring system is calibrated by each manufacturer using proprietary methods. We will develop a robust "SAR detector" and method to calibrate the SAR monitor, to allow a standardized comparison of SAR levels from different scanners. We will also develop technology to enable truly ergonomic "wearable" coils, instead of the bulky, intimidating cages currently in use. One component needed to achieve this is a better RF switch to make sensitive receive-only coils immune to the transmit pulses. The two types of switch in current use have problems such as generating heat or low reliability, and they both require control wires that complicate the cabling. We will realise a switch without these limitations. Finally, we will adapt the lightweight coils we designed for linac-MR radiation therapy machines to PET-MR scanners which also require coils that are essentially transparent to x-rays.