Canada Spends Logo

Explorez notre analyse du budget 2026

Grant: Research Tools and Instruments - Category 1 (<$150,000)

Queen's University

$67,200.00

Nonlinear optical coherence tomography

EF 2006-07

Résumé
The optical coherence tomography (OCT) microscope can produce micron-scale three-dimensional images to depths of several mm in living tissue.  Though it has made major inroads in ophthalmology, OCT suffers from several difficiencies including low contrast.  We propose to build a new instrument which will exploit the micron-scale resolution capabilities of OCT with the photon selectivity of nonlinear time-gating to improve imaging contrast and decrease data acquisition time.  Subpicosecond optical time gating, by sum-frequency mixing in a nonlinear crystal, rejects light (and its associated noise) from outside the gated time window before detection occurs.  This will yield significant improvements in imaging quality close to highly scattering media and at longer penetration depths.  Aliasing which causes ghost images and noise in current Fourier-domain implementations of OCT will also be avoided.  The time gating process is also beneficial since sample probing can be done with wavelengths around 1300nm which are optimal for sample penetration, while photodetection is done with visible light allowing the use of high performance silicon-based detector technology.  Time gating decreases the number of detector elements required thus dramatically reducing aquisition and processing time compared to standard Fourier-domain OCT systems.     This research program makes extensive use of our preexisting ultrafast infrastructure, our experience with optical pulse characterization, and our collaborations with other OCT researchers, industrial engineers and potential end users.  It is only the first step within an overall vision to integrate ultrafast optical material processing techniques with improved imaging modalities for clinical applications.  Two current graduate students require the equipment immediately for their research program.  An estimated seven additional Queen's students  (undergraduate and graduate) and at least two visiting researchers will have hands-on training on this equipment over the next three years.
Programme
Research Tools and Instruments - Category 1 (<$150,000)
Bénéficiaire
Emplacement
Ontario, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data

Tel que publié

Application id
344824-2007
Name nom
Fraser, James
Department département
Physics
Organization id
29
Institution établissement
Queen's University
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2006
Competition year année de concours
2007
Award amount
67200
Program id
EQPEQ
Program name en
Research Tools and Instruments - Category 1 (<$150,000)
Program name fr
Outils et instruments de recherche - catégorie 1 (<150 000$)
Group en
Discovery grants programs
Group fr
Programmes de subventions à la découverte
Committee code
28
Committee name en
Condensed Matter Physics
Committee name fr
Phys. de la matière condensée
Area of application code
518
Area of application group en
Manufacturing processes and products
Area of application group fr
Procédés et produits industriels
Area of application en
Medical equipment and apparatus
Area of application fr
Appareils et instruments médicaux
Research subject code
3110
Research subject group en
Physics
Research subject group fr
Physique
Research subject en
Optics (see also photon devices2505)
Research subject fr
Optique (voir aussi dispositifs photoniques, 2505)
Partie
1
Nb partie
1
Application title
Nonlinear optical coherence tomography
Keyword
NA
Application summary
The optical coherence tomography (OCT) microscope can produce micron-scale three-dimensional images to depths of several mm in living tissue.  Though it has made major inroads in ophthalmology, OCT suffers from several difficiencies including low contrast.  We propose to build a new instrument which will exploit the micron-scale resolution capabilities of OCT with the photon selectivity of nonlinear time-gating to improve imaging contrast and decrease data acquisition time.  Subpicosecond optical time gating, by sum-frequency mixing in a nonlinear crystal, rejects light (and its associated noise) from outside the gated time window before detection occurs.  This will yield significant improvements in imaging quality close to highly scattering media and at longer penetration depths.  Aliasing which causes ghost images and noise in current Fourier-domain implementations of OCT will also be avoided.  The time gating process is also beneficial since sample probing can be done with wavelengths around 1300nm which are optimal for sample penetration, while photodetection is done with visible light allowing the use of high performance silicon-based detector technology.  Time gating decreases the number of detector elements required thus dramatically reducing aquisition and processing time compared to standard Fourier-domain OCT systems.     This research program makes extensive use of our preexisting ultrafast infrastructure, our experience with optical pulse characterization, and our collaborations with other OCT researchers, industrial engineers and potential end users.  It is only the first step within an overall vision to integrate ultrafast optical material processing techniques with improved imaging modalities for clinical applications.  Two current graduate students require the equipment immediately for their research program.  An estimated seven additional Queen's students  (undergraduate and graduate) and at least two visiting researchers will have hands-on training on this equipment over the next three years.