Grant: Engage Grants Program
Ryerson University
$25,000.00
A model for long-term ground temperature response to geo-exchange
EF 2014-15
Résumé
Ground Source Heat Pumps (GSHPs) are a clean and sustainable alternative to conventional building heating and cooling technologies. GSHPs can provide space heating in the winter, by extracting heat from the deep ground, and cooling in the summer, by redirecting heat from the building back into the ground. Currently, the high upfront cost and long payback period of a GSHP is often alleviated by hybridizing the GSHP with an auxiliary heating/cooling system. Hybrid GSHPs are economically viable green alternatives, with the potential to become widespread in Canada.When there is an imbalance between the building's winter heating and summer cooling demands, the ground temperature can creep up or down over long-term operation. This temperature creep can reduce the efficiency of the GSHP, making it less economical, or in extreme cases, can render it inoperable. The phenomenon is know as 'ground fouling'. The company partner struggles to predict ground fouling from long term operation, and thus struggles to design around it.The proposed project seeks to develop a predictive computer model that can determine the long-term (5-20 year) ground temperature response to a proposed hybrid GSHP design. The approach that will be taken in the development of this model is to create a finite element model for heat transfer within the soil as a response to building loads, and integrate the model directly into the design process. Using this tool, the company partner will be able to test the long-term fidelity of proposed designs to alleviate the aforementioned problem. This improvement will contribute to the further development of Canada's sustainable technology deployment.
Programme
Engage Grants Program
Bénéficiaire
Emplacement
Ontario, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data
Tel que publié
Application id
477623-2014
Name nom
Dworkin, Seth
Department département
Mechanical and Industrial Engineering
Organization id
43
Institution établissement
Ryerson University
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2014
Competition year année de concours
2014
Award amount
25000
Program id
EGP
Program name en
Engage Grants Program
Program name fr
Programme de subventions d'engagement partenariat
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1553
Committee name en
Ontario Internal Decision Committee
Committee name fr
Comité de décision interne pour l'Ontario
Area of application code
305
Area of application group en
Energy resources
Area of application group fr
Ressources d'énergie
Area of application en
Energy storage and conversion
Area of application fr
Stockage et transformation de l'énergie
Research subject code
2107
Research subject group en
Mechanical engineering
Research subject group fr
Génie mécanique
Research subject en
Modelling, simulation and finite element methods
Research subject fr
Modélisation, simulation et méthodes des éléments finis
Partie
1
Nb partie
1
Application title
A model for long-term ground temperature response to geo-exchange
Keyword
NSERC
Application summary
Ground Source Heat Pumps (GSHPs) are a clean and sustainable alternative to conventional building heating and cooling technologies. GSHPs can provide space heating in the winter, by extracting heat from the deep ground, and cooling in the summer, by redirecting heat from the building back into the ground. Currently, the high upfront cost and long payback period of a GSHP is often alleviated by hybridizing the GSHP with an auxiliary heating/cooling system. Hybrid GSHPs are economically viable green alternatives, with the potential to become widespread in Canada.When there is an imbalance between the building's winter heating and summer cooling demands, the ground temperature can creep up or down over long-term operation. This temperature creep can reduce the efficiency of the GSHP, making it less economical, or in extreme cases, can render it inoperable. The phenomenon is know as 'ground fouling'. The company partner struggles to predict ground fouling from long term operation, and thus struggles to design around it.The proposed project seeks to develop a predictive computer model that can determine the long-term (5-20 year) ground temperature response to a proposed hybrid GSHP design. The approach that will be taken in the development of this model is to create a finite element model for heat transfer within the soil as a response to building loads, and integrate the model directly into the design process. Using this tool, the company partner will be able to test the long-term fidelity of proposed designs to alleviate the aforementioned problem. This improvement will contribute to the further development of Canada's sustainable technology deployment.