Grant: Collaborative Health Research Projects (NSERC partnered)
Polytechnique Montréal
$211,407.00
Optical guidance for safe and effective brain tumor biopsy
EF 2013-14
Résumé
Brain tumor treatment often involves open-cranium surgery to achieve maximum resection and provide survival benefits. However this is not always the best treatment option and the decision whether or not to proceed with surgery is informed by the suspected type and grade of the tumor, as well as by the risk/benefit assessment based on the increased likelihood of permanent neurological deficits for lesions located in areas controlling, e.g., motor and cognitive functions. When a precise diagnosis is required prior to or in place of surgery, a brain needle biopsy is used to collect tissue specimens. However, the standard technique often leads to diagnosis errors because of tumor samples being collected in areas not representative of the disease. Major complications can also arise due to hemorrhages caused by rupturing of a blood vessel during tissue extraction.
The objective of this project is to develop an optical technique that will improve patient safety by limiting the number of samples required to achieve an accurate diagnosis and by avoiding the risk of hemorrhage. An integrated optical biopsy needle will be developed detecting fluorescence, reflectance and inelastic scattering spectra that will be used to quantify tumor-specific biomarkers during the procedure. This information will be provided to the surgeon allowing him/her to decide where biopsy specimens should be extracted in order to avoid misdiagnosis. Concurrent with this, diffuse reflectance techniques will be developed to detect and localize blood vessels by quantifying the distortion of the hemoglobin absorption signature due to attenuation by intervening tissue. Not only will the new technology contribute to improving patient safety, but it will also reduce the economical burden on the Canadian health care system by, e.g., reducing the number of repeat procedures.
Programme
Collaborative Health Research Projects (NSERC partnered)
Bénéficiaire
Emplacement
Quebec, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
CIHR Funding Decisions Database
Tel que publié
Id
295511
Name
Leblond Frederic
Region
Québec
Country
Canada
Orgtype
Institution Paid; Research Institution
Partnername
Natural Sciences and Engineering Research Council of Canada (NSERC)
Instname2
Cancer Research
Theme2
Biomedical
Prcname2
Collaborative Health Research Projects - NSERC Partnered
Projecttitle
Optical guidance for safe and effective brain tumor biopsy
Programtype2
Operating Grants
Orgnameinp2
Polytechnique Montréal
Cihramount2
$211,407
Cihrequipment2
$0
Programname2
Collaborative Health Research Projects (NSERC partnered)
Keyworddelim
Biomedical Engineering 1102; Biomedical Technology 1901; Biopsy; Brain Tumours; Diffuse Optical Tomography; Engineering 1206; Fluorescence; Instrumentation And Measurements 2518; Neurosurgery; Raman Spectroscopy
Abstract
Brain tumor treatment often involves open-cranium surgery to achieve maximum resection and provide survival benefits. However this is not always the best treatment option and the decision whether or not to proceed with surgery is informed by the suspected type and grade of the tumor, as well as by the risk/benefit assessment based on the increased likelihood of permanent neurological deficits for lesions located in areas controlling, e.g., motor and cognitive functions. When a precise diagnosis is required prior to or in place of surgery, a brain needle biopsy is used to collect tissue specimens. However, the standard technique often leads to diagnosis errors because of tumor samples being collected in areas not representative of the disease. Major complications can also arise due to hemorrhages caused by rupturing of a blood vessel during tissue extraction.
The objective of this project is to develop an optical technique that will improve patient safety by limiting the number of samples required to achieve an accurate diagnosis and by avoiding the risk of hemorrhage. An integrated optical biopsy needle will be developed detecting fluorescence, reflectance and inelastic scattering spectra that will be used to quantify tumor-specific biomarkers during the procedure. This information will be provided to the surgeon allowing him/her to decide where biopsy specimens should be extracted in order to avoid misdiagnosis. Concurrent with this, diffuse reflectance techniques will be developed to detect and localize blood vessels by quantifying the distortion of the hemoglobin absorption signature due to attenuation by intervening tissue. Not only will the new technology contribute to improving patient safety, but it will also reduce the economical burden on the Canadian health care system by, e.g., reducing the number of repeat procedures.
Competitiondate
201310
Approvedterm2
3 yrs 0 mth
Pinamesdelim
Leblond, Frederic; Boudoux, Caroline; Collins, Donald L; Lesage, Frédéric; Petrecca, Kevin; Wilson, Brian C
Approvedterm
3 ans 0 mois
Cihrcontribution2
Knowledge Translation Branch~ $211,407~ $0~