Grant: Discovery Grants Program - Individual
Carleton University
$17,638.00
X-ray dual-mode imager comprising radiography and coherent scatter
EF 2023-24
Résumé
Despite the advances in MRI (magnetic resonance imaging), nuclear medicine, and ultrasound, x-ray imaging continues to be a principal medical tool to look inside the body. Physics innovations and current detector technologies now allow x rays to be used in new ways to generate more information. These approaches can be used for other types of x-ray imaging, such as security inspection of packages. All medical x-ray imaging today uses the "primary" or transmitted x rays to form a "shadow" picture of the patient. Scattered x rays, however, comprise up to 90% of the radiation at the image receptor and are another information source. Our lab's focus is to develop an x-ray imaging system that uses scatter as well as primary. In recent years we have built a prototype scatter imaging system at the Canadian Light Source synchrotron in Saskatoon, and then a more practical system in our lab at Carleton University in Ottawa using a conventional x-ray source. We have investigated means to make the x-ray acquisition as fast as possible and have achieved scan times of a few minutes at the synchrotron and under 10 minutes with the conventional source. We will: (1) Apply our system to the imaging of bone and cartilage samples to better characterize bone health and diagnose osteoporosis. (2) Investigate ways to make a high-resolution conventional image at the same time as the scatter image. These innovations in x-ray imaging are commercializable and applicable beyond medicine to industrial nondestructive testing, to security imaging, and to all other areas in which x rays are shone through an object. We will seek further funding to help commercialize once the technologcal approach has been further refined.
Programme
Discovery Grants Program - Individual
Bénéficiaire
Emplacement
Ontario, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data
Tel que publié
Application id
RGPIN-2022-04893
Name nom
Johns, Paul
Department département
Physics
Organization id
23
Institution établissement
Carleton University
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2023
Competition year année de concours
2022
Award amount
17638
Program id
RGPIN
Program name en
Discovery Grants Program - Individual
Program name fr
Programme de subventions à la découverte - individuelles
Group en
DISCOVERY RESEARCH
Group fr
RECHERCHE AXÉE SUR LA DÉCOUVERTE
Committee code
1505
Committee name en
Physics
Committee name fr
Physique
Area of application code
518
Area of application group en
Manufacturing processes and products
Area of application group fr
Procédés et produits industriels
Area of application en
Medical equipment and apparatus
Area of application fr
Appareils et instruments médicaux
Research subject code
1901
Research subject group en
Biomedical engineering
Research subject group fr
Biomedical technology
Research subject en
Génie biomédical
Research subject fr
Technologie biomédicale
Application title
X-ray dual-mode imager comprising radiography and coherent scatter
Keyword
biomedical imaging; coherent x-ray scatter; non-destructive testing; scattered x rays; security imaging; x-ray bone mineral densitometry; x-ray dental camera; x-ray diffraction; x-ray image contrast; x-ray scatter imaging
Application summary
Despite the advances in MRI (magnetic resonance imaging), nuclear medicine, and ultrasound, x-ray imaging continues to be a principal medical tool to look inside the body. Physics innovations and current detector technologies now allow x rays to be used in new ways to generate more information. These approaches can be used for other types of x-ray imaging, such as security inspection of packages. All medical x-ray imaging today uses the "primary" or transmitted x rays to form a "shadow" picture of the patient. Scattered x rays, however, comprise up to 90% of the radiation at the image receptor and are another information source. Our lab's focus is to develop an x-ray imaging system that uses scatter as well as primary. In recent years we have built a prototype scatter imaging system at the Canadian Light Source synchrotron in Saskatoon, and then a more practical system in our lab at Carleton University in Ottawa using a conventional x-ray source. We have investigated means to make the x-ray acquisition as fast as possible and have achieved scan times of a few minutes at the synchrotron and under 10 minutes with the conventional source. We will: (1) Apply our system to the imaging of bone and cartilage samples to better characterize bone health and diagnose osteoporosis. (2) Investigate ways to make a high-resolution conventional image at the same time as the scatter image. These innovations in x-ray imaging are commercializable and applicable beyond medicine to industrial nondestructive testing, to security imaging, and to all other areas in which x rays are shone through an object. We will seek further funding to help commercialize once the technologcal approach has been further refined.