Canada Spends Logo

Explorez notre analyse du budget 2026

Grant: Collaborative Research and Development Grants

University of Waterloo

$60,000.00

Predictive dynamic simulation of human movement following hip replacement

EF 2021-22

Résumé
Between 2014-2015 in Canada, there were over 50,000 hip replacement surgeries; of these, 8.5% required a subsequent surgery to correct for a faulty placement of the hip implants. Intellijoint Surgical of Waterloo, Canada, has developed a real-time navigation system for surgeons to monitor the precise placement of these implants. This system has been used in over 5000 surgeries to date, but it cannot tell the surgeon where the implants should be positioned and oriented to minimize a risk of a hip dislocation.The purpose of this collaborative research is to develop multibody dynamic models and computer simulations to determine the best position and orientation of implants in a hip replacement surgery. We will focus on sit-to-stand motions that present high dislocation risks following surgery, and develop predictive simulations that include the effects of spine flexibility, forward/backward tilting of the pelvis, joint reaction forces, and subject-specific data. There is no sit-to-stand model in the literature that includes these important effects. Using predictive simulations and optimization algorithms, we can then determine the position and orientation of the hip implants that minimize the risk of hip dislocation.The resulting algorithms can be commercialized by Intelljoint to provide pre-surgery planning capability to their current navigation product. The end result will be a greater market share for this Canadian company, as well as a higher success rate for hip replacement surgeries, greater quality of life for Canadian patients, and a reduction in health care costs in our country.
Programme
Collaborative Research and Development Grants
Emplacement
Ontario, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data

Tel que publié

Application id
530654-2018
Name nom
McPhee, John
Department département
Systems Design Engineering
Organization id
33
Institution établissement
University of Waterloo
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2021
Competition year année de concours
2018
Award amount
60000
Program id
CRDPJ
Program name en
Collaborative Research and Development Grants
Program name fr
Subventions de recherche et développement coopérative
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
96
Committee name en
RPP Internal Decision Cttee
Committee name fr
Cté de décision interne - PPR
Area of application code
1200
Area of application group en
Advancement of knowledge
Area of application group fr
Avancement des connaissances
Area of application en
Advancement of knowledge
Area of application fr
Avancement des connaissances
Research subject code
2102
Research subject group en
Mechanical engineering
Research subject group fr
Génie mécanique
Research subject en
Dynamics
Research subject fr
Dynamique
Installment
inst:5
Partie
1
Nb partie
5
Application title
Predictive dynamic simulation of human movement following hip replacement
Keyword
NSERC
Application summary
Between 2014-2015 in Canada, there were over 50,000 hip replacement surgeries; of these, 8.5% required a subsequent surgery to correct for a faulty placement of the hip implants. Intellijoint Surgical of Waterloo, Canada, has developed a real-time navigation system for surgeons to monitor the precise placement of these implants. This system has been used in over 5000 surgeries to date, but it cannot tell the surgeon where the implants should be positioned and oriented to minimize a risk of a hip dislocation.The purpose of this collaborative research is to develop multibody dynamic models and computer simulations to determine the best position and orientation of implants in a hip replacement surgery. We will focus on sit-to-stand motions that present high dislocation risks following surgery, and develop predictive simulations that include the effects of spine flexibility, forward/backward tilting of the pelvis, joint reaction forces, and subject-specific data. There is no sit-to-stand model in the literature that includes these important effects. Using predictive simulations and optimization algorithms, we can then determine the position and orientation of the hip implants that minimize the risk of hip dislocation.The resulting algorithms can be commercialized by Intelljoint to provide pre-surgery planning capability to their current navigation product. The end result will be a greater market share for this Canadian company, as well as a higher success rate for hip replacement surgeries, greater quality of life for Canadian patients, and a reduction in health care costs in our country.