Grant: Catalyst Grant: Bone Health
University of Saskatchewan
$52,292.00
Diffraction Enhanced Imaging of Trabecular Bone Architecture at the Wrist
EF 2010-11
Résumé
In Canada osteoporotic fractures result in direct health care costs that exceed a billion dollars annually. Fractures are related to compromised bone strength - which is a reflection of both the amount of tissue within a bone (bone quantity) and the way in which the tissue is arranged (bone quality). Current clinical assessment of bone strength is based upon 'bone density scans', performed using a technology known as dual energy x-ray absorptiometry, or DXA. As the common name of these scans suggests, this technology focuses on density - a reflection of bone quantity but not quality. The development of improved methods for visualizing and quantifying bone architectural quality is, therefore, critical. Achieving such an advance would not only improve the capacity to detect bone loss and track the effects of treatment but, more significantly, would also improve the opportunity to intervene and prevent disease through earlier identification of at-risk individuals. Increasing evidence suggests the antecedents of bone fractures may lie in adolescence or even earlier. As such, an ideal methodology for research and clinical applications would be one which enables safe imaging of bone quality across the human lifespan - including childhood. We proposed to test a new imaging approach known as 'diffraction enhanced imaging' or DEI. This technology, which has been developed in powerful synchrotron facilities, has the potential to provide unique information about the internal structure (quality) of a bone and to do so with less radiation dose than conventional methods. We will test this approach by imaging post-mortem human wrist specimens with both the Biomedial Imaging and Therapy beam lines of the Canadian Light Source synchrotron and comparing the results with cutting edge 3D clinical imaging tools. Our specific goals are validation and optimization of the DEI method for bone assessment.
Programme
Catalyst Grant: Bone Health
Bénéficiaire
Emplacement
Saskatchewan, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
CIHR Funding Decisions Database
Tel que publié
Id
207823
Name
Cooper David M
Region
Saskatchewan
Country
Canada
Orgtype
Institution Paid; Research Institution
Instname2
Musculoskeletal Health and Arthritis
Theme2
Biomedical
Prcname2
Catalyst Grant: Bone Health
Projecttitle
Diffraction Enhanced Imaging of Trabecular Bone Architecture at the Wrist
Programtype2
Operating Grants
Orgnameinp2
University of Saskatchewan
Cihramount2
$52,292
Cihrequipment2
$0
Programname2
Catalyst Grant: Bone Health
Keyworddelim
Bone; Diffraction Enhanced Imaging; Hr-Pqct; Imaging; Osteoporosis; Radius; Synchrotron; Wrist
Abstract
In Canada osteoporotic fractures result in direct health care costs that exceed a billion dollars annually. Fractures are related to compromised bone strength - which is a reflection of both the amount of tissue within a bone (bone quantity) and the way in which the tissue is arranged (bone quality). Current clinical assessment of bone strength is based upon 'bone density scans', performed using a technology known as dual energy x-ray absorptiometry, or DXA. As the common name of these scans suggests, this technology focuses on density - a reflection of bone quantity but not quality. The development of improved methods for visualizing and quantifying bone architectural quality is, therefore, critical. Achieving such an advance would not only improve the capacity to detect bone loss and track the effects of treatment but, more significantly, would also improve the opportunity to intervene and prevent disease through earlier identification of at-risk individuals. Increasing evidence suggests the antecedents of bone fractures may lie in adolescence or even earlier. As such, an ideal methodology for research and clinical applications would be one which enables safe imaging of bone quality across the human lifespan - including childhood. We proposed to test a new imaging approach known as 'diffraction enhanced imaging' or DEI. This technology, which has been developed in powerful synchrotron facilities, has the potential to provide unique information about the internal structure (quality) of a bone and to do so with less radiation dose than conventional methods. We will test this approach by imaging post-mortem human wrist specimens with both the Biomedial Imaging and Therapy beam lines of the Canadian Light Source synchrotron and comparing the results with cutting edge 3D clinical imaging tools. Our specific goals are validation and optimization of the DEI method for bone assessment.
Competitiondate
201006
Approvedterm2
1 yr 0 mth
Pinamesdelim
Cooper, David M
Approvedterm
1 an 0 mois
Cihrcontribution2
Inst of Musculoskel Hlth &Arth~ $52,292~ $0~