Canada Spends Logo

Explorez notre analyse du budget 2026

Grant: Discovery Grants Program - Individual

University of Ottawa

$31,000.00

Data acquisition optimization for smart monitoring networks

EF 2018-19

Résumé
Data Acquisition Systems (DAS) digitize analog signals in order to be digitally processed by embedded systems in monitoring or control applications. DAS are at the front-end of the chain of data processing and, as such, any quantization and sampling error that is input to the computing system may cause catastrophic failures in the correct interpretation of the acquired signals. Current DAS have no provisions for Measurement Quality Assurance (MQA) to certify in real-time the correctness and trustworthiness of measurements by providing metadata on the precision, accuracy, conditions and utility of measurements, and which are essential requirements for operation in remote unsupervised environments. The lack of this information made impossible the development of viable monitoring technologies for personal healthcare applications or constrained their proliferation in other domains. Losing data because of unreliable operation, due to scarce resources caused by unexpected events, fuelled a lack of confidence in these technologies, as well. *In order to address the resources efficiency, reliability and versatility, while increasing accuracy, trustworthiness and adequacy of the collected information, we propose to conceiving, developing and optimizing architectures, algorithms and models at different levels of data acquisition. The quantization process will be marked by MQA qualifiers which will objectively and globally characterize the measurands (acquired signals), measurement uncertainty, acquisition conditions (compliance with the requirements of standards), and measuring devices (Hardware and Software), including the accuracy of the indirect measurement algorithms.*This research will employ compressed sensing techniques in order to reduce digitization relative errors and optimize the density of transmitted data. Floating-point differential quantization methods will be used to insure a broad dynamic range of the acquired signals and eliminate redundant information. Adaptive sampling rate algorithms will be studied in the context of the acquisition of sparse signals with strong deterministic components, but which may occasionally deviate from stable operation. Adaptive compressive sampling and quantization will mitigate the power consumption if resources get scarcely, while maximizing the data acquisition capacity and minimizing the measurement uncertainty.*One of the most challenging applications of DAS is the non-invasive personal health monitoring. Assessment of quotidian physiological parameters relies on measurement and processing of bio-signals that are strongly correlated with these parameters and which can be acquired non-invasively. Optimization of methods in estimation of physiological parameters based on multi-sensors and algorithms fusion will be a central objective of this research plan. The amount of collected data will be optimally adapted to the resources constraints. Current technologies require more power for data transmission rather than processing. Hence, the local DAS management will decide to calculate locally the parameters whenever is possible, to minimize communication, in order to save energy.*This research project will be validated by implementing its findings on a multi-sensor DAS platform that will be capable of fusing data, adapting its operation and structure to the dynamics of the monitored signals, selftesting, self-calibrating and estimating the MQA parameters.*This project aims at improving the quality of health services in Canada by enabling people to monitor and report their health conditions. Not only will medical practitioners have access to trustworthy data, but governmental agencies will also be able to concurrently monitor the efficiency of their policies and investments.
Programme
Discovery Grants Program - Individual
Bénéficiaire
Emplacement
Ontario, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data

Tel que publié

Application id
RGPIN-2014-05827
Name nom
Groza, Voicu
Department département
Electrical Engineering and Computer Science , School of - science informatique e
Organization id
28
Institution établissement
University of Ottawa
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2018
Competition year année de concours
2014
Award amount
31000
Program id
RGPIN
Program name en
Discovery Grants Program - Individual
Program name fr
Programme de subventions à la découverte - individuelles
Group en
Discovery grants programs
Group fr
Programmes de subventions à la découverte
Committee code
1510
Committee name en
Electrical and Computer Engineering
Committee name fr
Génie électrique et informatique
Area of application code
1102
Area of application group en
Health, education and social services
Area of application group fr
Santé publique, éducation et services sociaux
Area of application en
Biomedical engineering
Area of application fr
Génie biomédical
Research subject code
1901
Research subject group en
Biomedical engineering
Research subject group fr
Génie biomédical
Research subject en
Biomedical technology
Research subject fr
Technologie biomédicale
Partie
5
Nb partie
5
Application title
Data acquisition optimization for smart monitoring networks
Keyword
NSERC
Application summary
Data Acquisition Systems (DAS) digitize analog signals in order to be digitally processed by embedded systems in monitoring or control applications. DAS are at the front-end of the chain of data processing and, as such, any quantization and sampling error that is input to the computing system may cause catastrophic failures in the correct interpretation of the acquired signals. Current DAS have no provisions for Measurement Quality Assurance (MQA) to certify in real-time the correctness and trustworthiness of measurements by providing metadata on the precision, accuracy, conditions and utility of measurements, and which are essential requirements for operation in remote unsupervised environments. The lack of this information made impossible the development of viable monitoring technologies for personal healthcare applications or constrained their proliferation in other domains. Losing data because of unreliable operation, due to scarce resources caused by unexpected events, fuelled a lack of confidence in these technologies, as well. *In order to address the resources efficiency, reliability and versatility, while increasing accuracy, trustworthiness and adequacy of the collected information, we propose to conceiving, developing and optimizing architectures, algorithms and models at different levels of data acquisition. The quantization process will be marked by MQA qualifiers which will objectively and globally characterize the measurands (acquired signals), measurement uncertainty, acquisition conditions (compliance with the requirements of standards), and measuring devices (Hardware and Software), including the accuracy of the indirect measurement algorithms.*This research will employ compressed sensing techniques in order to reduce digitization relative errors and optimize the density of transmitted data. Floating-point differential quantization methods will be used to insure a broad dynamic range of the acquired signals and eliminate redundant information. Adaptive sampling rate algorithms will be studied in the context of the acquisition of sparse signals with strong deterministic components, but which may occasionally deviate from stable operation. Adaptive compressive sampling and quantization will mitigate the power consumption if resources get scarcely, while maximizing the data acquisition capacity and minimizing the measurement uncertainty.*One of the most challenging applications of DAS is the non-invasive personal health monitoring. Assessment of quotidian physiological parameters relies on measurement and processing of bio-signals that are strongly correlated with these parameters and which can be acquired non-invasively. Optimization of methods in estimation of physiological parameters based on multi-sensors and algorithms fusion will be a central objective of this research plan. The amount of collected data will be optimally adapted to the resources constraints. Current technologies require more power for data transmission rather than processing. Hence, the local DAS management will decide to calculate locally the parameters whenever is possible, to minimize communication, in order to save energy.*This research project will be validated by implementing its findings on a multi-sensor DAS platform that will be capable of fusing data, adapting its operation and structure to the dynamics of the monitored signals, selftesting, self-calibrating and estimating the MQA parameters.*This project aims at improving the quality of health services in Canada by enabling people to monitor and report their health conditions. Not only will medical practitioners have access to trustworthy data, but governmental agencies will also be able to concurrently monitor the efficiency of their policies and investments.