Canada Spends Logo

Explorez notre analyse du budget 2026

Grant: Alliance Grants

Carleton University

$30,000.00

A comprehensive study on enhancing the fire resistance of Glass Fiber-Reinforced Polymer (GFRP) reinforced concrete columns and slabs

EF 2023-24

Résumé
This project aims to provide a holistic investigation of Glass fibre reinforced polymer (GFRP) reinforced concrete members in fire, namely columns and slabs. This research will have three main experimental phases: (1) standard pullout tests on MST bars in an environmental chamber; (2) intermediate and full-scale standard fire tests will be conducted on GFRP-reinforced concrete slabs with intumescent coating at the ends of the slabs; and (3) a full-scale column entirely reinforced with GFRP bars will be tested under standard fire for the first time in North America. To date, the loss and degradation of bond strength of FRP reinforcing bars at high temperatures has been identified as the main cause of the inferior fire performance of FRP-reinforced concrete (RC) elements compared to steel RC ones. The test results have revealed that if temperatures at both ends of an FRP bar remain below its glass transition temperature the bond failure of the FRP RC member will significantly improve. To achieve this, the anchorage zones in FRP RC members are recommended to be protected from direct fire exposures to delay the temperature propagation into the embedded FRP reinforcing bars at the anchorage zones. Recently, the application of intumescent coatings with very thin layers has shown promising results with delayed temperature propagation into the concrete. The thin-film intumescent coatings greatly protect structural elements against severe temperatures that can occur in fires. The intumescent coatings are an easy-to-apply and cost-effective alternative to conventional passive fire protection layers. The previously mentioned tests will be used to examine the performance of GFRP reinforced concrete columns, as well as the behaviour of GFRP stirrups and GFRP longitudinal bars during a fire. Through this partnership, MST Rebar will be confident in the fire resistance of GFRP RC columns and offer practical measures to enhance the fire resistance of GFRP RC slabs. Canadian codes, such as CSA-S806, are specifically developed to promote GFRP RC structures. The outcome of this research will provide knowledge in developing provisions for CSA-S806 in Canada.
Programme
Alliance Grants
Bénéficiaire
Emplacement
Ontario, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data

Tel que publié

Application id
580337-2022
Name nom
Hajiloo, Hamzeh H
Department département
Civil and Environmental Engineering
Organization id
23
Institution établissement
Carleton University
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2023
Competition year année de concours
2022
Award amount
30000
Program id
ALLRP
Program name en
Alliance Grants
Program name fr
Subventions Alliance
Group en
RESEARCH PARTNERSHIPS
Group fr
PARTENARIATS DE RECHERCHE
Committee code
96
Committee name en
RPP Internal Decision Cttee
Committee name fr
Cté de décision interne - PPR
Area of application code
601
Area of application group en
Construction, urban and rural planning
Area of application group fr
Construction, urbanisme et aménagement rural
Area of application en
Structural engineering
Area of application fr
Génie des charpentes
Research subject code
1105
Research subject group en
Structural engineering
Research subject group fr
Structural materials
Research subject en
Génie des structures
Research subject fr
Matériaux de structure
Application title
A comprehensive study on enhancing the fire resistance of Glass Fiber-Reinforced Polymer (GFRP) reinforced concrete columns and slabs
Keyword
bond degradation; Codes and standards; Durability; Fibre Reinforced polymers; Fire safety; Full-scale fire tests; Reinforced concrete; Structural fire engineering
Application summary
This project aims to provide a holistic investigation of Glass fibre reinforced polymer (GFRP) reinforced concrete members in fire, namely columns and slabs. This research will have three main experimental phases: (1) standard pullout tests on MST bars in an environmental chamber; (2) intermediate and full-scale standard fire tests will be conducted on GFRP-reinforced concrete slabs with intumescent coating at the ends of the slabs; and (3) a full-scale column entirely reinforced with GFRP bars will be tested under standard fire for the first time in North America. To date, the loss and degradation of bond strength of FRP reinforcing bars at high temperatures has been identified as the main cause of the inferior fire performance of FRP-reinforced concrete (RC) elements compared to steel RC ones. The test results have revealed that if temperatures at both ends of an FRP bar remain below its glass transition temperature the bond failure of the FRP RC member will significantly improve. To achieve this, the anchorage zones in FRP RC members are recommended to be protected from direct fire exposures to delay the temperature propagation into the embedded FRP reinforcing bars at the anchorage zones. Recently, the application of intumescent coatings with very thin layers has shown promising results with delayed temperature propagation into the concrete. The thin-film intumescent coatings greatly protect structural elements against severe temperatures that can occur in fires. The intumescent coatings are an easy-to-apply and cost-effective alternative to conventional passive fire protection layers. The previously mentioned tests will be used to examine the performance of GFRP reinforced concrete columns, as well as the behaviour of GFRP stirrups and GFRP longitudinal bars during a fire. Through this partnership, MST Rebar will be confident in the fire resistance of GFRP RC columns and offer practical measures to enhance the fire resistance of GFRP RC slabs. Canadian codes, such as CSA-S806, are specifically developed to promote GFRP RC structures. The outcome of this research will provide knowledge in developing provisions for CSA-S806 in Canada.