Canada Spends Logo

Explorez notre analyse du budget 2026

Grant: Alliance Grants

École de technologie supérieure

$30,000.00

Air flow analysis, modelling and optimization for wind-driven rooftop ventilators

EF 2024-25

Résumé
Proper attic ventilation is important for buildings and homes. Excess humidity can lead to condensation, which can have serious health and financial consequences for inhabitants by promoting mould growth and compromising constituent materials (e.g., insulation, nails, wood, shingles). Excess heat increases the moisture carrying capacity of air, increases cooling costs in summer and can lead to ice damming in winter. The performance of an attic ventilation system should be evaluated by its ability to promote air exchange between the attic and the exterior, which depends above all on the design and placement of roof ventilators. Currently, the recommendations of the National Building Code of Canada do not consider the performance of the attic ventilation system as a whole. There is therefore a clear need to revise attic ventilation standards in Canada and to establish a reference framework to evaluate attic ventilation system performance. Passive roof ventilators rely solely on the natural rising of hot humid air. Active roof ventilators present a more effective alternative. Active ventilators, through specific design features, take advantage of wind speed to produce a local reduction in pressure that draws air from the attic. The higher the wind speed, the better the extraction rate. This partnership between Ventilation Maximum and École de technologie supérieure has as its main objective to conduct a comprehensive fluid dynamics study of the principles and mechanics of active ventilators, to derive pointers for design optimization and to evaluate the performance of a state-of-the-art active roof ventilator as a function of wind speed and direction. This work will advance knowledge regarding how airflow behaviour affects roof ventilator performance, help improve designs and offer supporting evidence for potential national building code modifications. This research is expected to contribute toward placing Canada in an international leadership position in the attic ventilation sector by advancing Canadian ventilator technology and boosting its competitiveness.
Programme
Alliance Grants
Emplacement
Quebec, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data

Tel que publié

Application id
593793-2024
Name nom
Di Labbio, Giuseppe G
Department département
Génie mécanique
Organization id
53
Institution établissement
École de technologie supérieure
Province en
Québec
Province fr
Québec
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2024
Competition year année de concours
2024
Award amount
30000
Program id
ALLRP
Program name en
Alliance Grants
Program name fr
Subventions Alliance
Group en
RESEARCH PARTNERSHIPS
Group fr
PARTENARIATS DE RECHERCHE
Committee code
96
Committee name en
RPP Internal Decision Cttee
Committee name fr
Cté de décision interne - PPR
Area of application code
1200
Area of application group en
Advancement of knowledge
Area of application group fr
Avancement des connaissances
Area of application en
Advancement of knowledge
Area of application fr
Avancement des connaissances
Research subject code
2100
Research subject group en
Mechanical engineering
Research subject group fr
Génie mécanique
Research subject en
Mechanical engineering
Research subject fr
Génie mécanique
Field of research list names en
Not available
Field of research list names fr
Non disponible
Socioeconomic objective list names en
Not available
Socioeconomic objective list names fr
Non disponible
Application title
Air flow analysis, modelling and optimization for wind-driven rooftop ventilators
Keywords
attic ventilation; fluid dynamics; reduced-order modelling; roof ventilators
Application summary
Proper attic ventilation is important for buildings and homes. Excess humidity can lead to condensation, which can have serious health and financial consequences for inhabitants by promoting mould growth and compromising constituent materials (e.g., insulation, nails, wood, shingles). Excess heat increases the moisture carrying capacity of air, increases cooling costs in summer and can lead to ice damming in winter. The performance of an attic ventilation system should be evaluated by its ability to promote air exchange between the attic and the exterior, which depends above all on the design and placement of roof ventilators. Currently, the recommendations of the National Building Code of Canada do not consider the performance of the attic ventilation system as a whole. There is therefore a clear need to revise attic ventilation standards in Canada and to establish a reference framework to evaluate attic ventilation system performance. Passive roof ventilators rely solely on the natural rising of hot humid air. Active roof ventilators present a more effective alternative. Active ventilators, through specific design features, take advantage of wind speed to produce a local reduction in pressure that draws air from the attic. The higher the wind speed, the better the extraction rate. This partnership between Ventilation Maximum and École de technologie supérieure has as its main objective to conduct a comprehensive fluid dynamics study of the principles and mechanics of active ventilators, to derive pointers for design optimization and to evaluate the performance of a state-of-the-art active roof ventilator as a function of wind speed and direction. This work will advance knowledge regarding how airflow behaviour affects roof ventilator performance, help improve designs and offer supporting evidence for potential national building code modifications. This research is expected to contribute toward placing Canada in an international leadership position in the attic ventilation sector by advancing Canadian ventilator technology and boosting its competitiveness.