Canada Spends Logo

Explorez notre analyse du budget 2026

Grant: Engage Grants Program

Ryerson University

$25,000.00

Integrating velo/zerometer technology into an advanced building automation control system

EF 2010-11

Résumé
Over the last three decades new technologies in the construction industry were responsible for lowering the Canadian residential annual heating energy demand from 300 ekWh/m2 (1970's average) to 110 ekWh/m2 per year (average for houses built according to the R-2000 Standard requirements). With careful design and detailing, it is possible to achieve annual heating demands of less than 15 ekWh/m2 according to Passive House Standard requirements. However, as was pointed out by the National Energy Board, the deciding factors in residential stock energy reduction is not a technology, but how the technology is used by consumers. There exists an opportunity to create a building control system to optimize the current use of technologies in order to reduce operational energy demand. The key challenge in the proposed research project is the integration of monitoring, simulation, reporting and control devices in a typical building environment. Integration of Zerofootprint's technology into a unique control/automation system is a complex multi-tiered research problem comprising computer programming, physical scientific analysis, visualization strategies and automation optimization. The specific objective of the research project is the integration of Velo/Zero MeterTM technology in parallel to development of an energy flow monitoring/control system to measure and display on-site real time energy use and heat, air and moisture (HAM) transfer through the building envelope. While most of the existing control systems are primarily intended for control of building's HVAC equipment, having the real-time monitoring component as a secondary objective, the proposed project is meant, first and foremost, as a tool to raise awareness of a building owner in his or her everyday environmental impact through integration of the Zero Meter TM. The Zero MeterTM will provide scientifically grounded information on energy and heat, air and moisture (HAM) processes in the building, and thus encourage users to responsibly act using educated actions towards a more sustainable way of resource consumption.
Programme
Engage Grants Program
Bénéficiaire
Emplacement
Ontario, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data

Tel que publié

Application id
412004-2010
Name nom
Richman, Russell
Department département
Architectural Science
Organization id
43
Institution établissement
Ryerson University
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2010
Competition year année de concours
2010
Award amount
25000
Program id
EGP
Program name en
Engage Grants Program
Program name fr
Programme de subventions d'engagement partenariat
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1553
Committee name en
Ontario Internal Decision Committee
Committee name fr
Comité de décision interne pour l'Ontario
Area of application code
306
Area of application group en
Energy resources
Area of application group fr
Ressources d'énergie
Area of application en
Energy efficiency
Area of application fr
Efficacité énergétique
Research subject code
1000
Research subject group en
Civil engineering
Research subject group fr
Génie civil
Research subject en
Civil engineering
Research subject fr
Génie civil
Partie
1
Nb partie
1
Application title
Integrating velo/zerometer technology into an advanced building automation control system
Keyword
NSERC
Application summary
Over the last three decades new technologies in the construction industry were responsible for lowering the Canadian residential annual heating energy demand from 300 ekWh/m2 (1970's average) to 110 ekWh/m2 per year (average for houses built according to the R-2000 Standard requirements). With careful design and detailing, it is possible to achieve annual heating demands of less than 15 ekWh/m2 according to Passive House Standard requirements. However, as was pointed out by the National Energy Board, the deciding factors in residential stock energy reduction is not a technology, but how the technology is used by consumers. There exists an opportunity to create a building control system to optimize the current use of technologies in order to reduce operational energy demand. The key challenge in the proposed research project is the integration of monitoring, simulation, reporting and control devices in a typical building environment. Integration of Zerofootprint's technology into a unique control/automation system is a complex multi-tiered research problem comprising computer programming, physical scientific analysis, visualization strategies and automation optimization. The specific objective of the research project is the integration of Velo/Zero MeterTM technology in parallel to development of an energy flow monitoring/control system to measure and display on-site real time energy use and heat, air and moisture (HAM) transfer through the building envelope. While most of the existing control systems are primarily intended for control of building's HVAC equipment, having the real-time monitoring component as a secondary objective, the proposed project is meant, first and foremost, as a tool to raise awareness of a building owner in his or her everyday environmental impact through integration of the Zero Meter TM. The Zero MeterTM will provide scientifically grounded information on energy and heat, air and moisture (HAM) processes in the building, and thus encourage users to responsibly act using educated actions towards a more sustainable way of resource consumption.